Configuration Radio Channel 1; Configuration Radio Channel 2; Flashing Light/ Lamps Configuration; Configuration Of The Signalling Lights On The Barrier - Roger Technology AG/CTRL AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 80
76 00
Configuration radio channel 1°
77 01
Configuration radio channel 2°
00
PP
01
PEDESTRIAN
02
OPEN
03
CLOSE
04
STOP
07
PP with safety configuration (through radio function no.2)
08
PEDESTRIAN with safety confirmation (through radio function no.2)
09
OPEN with safety confirmation (through radio function no.2)
10
CLOSE with safety confirmation (through radio function no.2)
The remote command with safety confirmation (values
of a button on the remote control that can enable the automation; this function can be enabled in a freely
and independently manner for both of the two functions PR1 and PR2 available on the plug-in receiver.
Example: by setting parameters
on function 1 of the radio and key CHB from the remote control stored on function 2 of the radio, by
activating the key CHA a count-down will start, and only if within 2" the key CHB activates, the "step-by-
step" command will be performed. If CHB is enabled, the pedestrian opening command will be immediately
activated.
78 02

Flashing light/ lamps Configuration

00
STILL (the flashing is given by the electronics of the lamp)
01
slow flashing activation
02
slow flashing activation while opening; quick flashing activation while closing
7-
NOTE: parameter
The flashing light turns on when there is a movement phase there can be a continuous activation (for
flashing lights with temporised electronics on board) or directly controlled by the control unit (for flashing
lights made of a simple light).
If setting the parameter
mechanical stop, the flashing frequency decreases.
79 00

Configuration of the signalling lights on the barrier

00
OFF (lights always disabled)
01
lights always on
02
lights on when the barrier still, flashing when the barrier is moving
03
quick blinking lights when the barrier is still, flashing when the barrier is moving
4-
NOTE: parameter
80 00

Clock Configuration

00
When the clock input is closed (ORO), opens it and then ignores all other commands
01
When the clock input is closed (ORO), opens it but accepts any other commands
36
76  07
and
in standard mode
78  01
02
or
, in the final movement phase, when the barrier approaches the
in standard mode
07
08
09
-
-
77  01
, using the key CHA from the remote control stored
10
-
) prevents the erroneous pressure