• starting from the moment in which the barrier
stands still (mechanically hooked) the control
unit will perform a second position reading, with
subsequent blinking signalling.
Controlling the angular position of the barrier, the
first command after the manual movement of the
barrier will be fully operative, allowing therefore
the performance of standard accelerations and
decelerations.
10
Extended operating mode
NOTE: if using only the standard mode, the value of
the hidden parameters - for a new control unit or
number of the parameter
selectable values
A1 02
Selection of the barrier length
00
up to 3m
01
from 3m to 4.5
02
from 4.5m to 6m (the barrier body contains a gear reducer specific for this application)
0-
NOTE: parameter
A correct selection of the length of the barrier, also made in relation to the body of the machine to be used,
is fundamental for obtaining a proper functioning without risking causing any damages to the mechanical
part. Regarding the value of this parameter, there are some limitations concerning the parameters:
33
34
40
41
43
,
,
,
,
A2 00
Automatic closing after pause time
00
OFF (automatic closing will not be performed)
01
15
NUMBER of closing attempts (interrupted by the photocell) before leaving it opened
-
99
tries to close without limiting the number of attempts
1-
NOTE: parameter
In order to restore closing, this parameter should be set to a number different from
99
value
the closing will always be performed after the pause time. If setting a number within
that is the maximum number of closing attempts that will be performed. For example, by setting the value
01
, if during the closing process, something will cross the beam of the inversion photocells, the barrier
would reopen without closing (only one closing attempt is just been performed).
The automatic closing is performed only if the barrier reaches the full opened position.
NOTE: the value of the parameter
49
value of parameter
A2 00
00
01
15
-
in standard mode
44
65
,
and
.
in standard mode
49
is subordinated to the value chosen for parameter
can be equal to that of parameter
after every restore of the standard parameters - is
the one indicated next to the parameter, and is the
one considered to be the most useful in installations.
WARNING! Depending on the selected mode, some
parameters may not be displayed, as they do not
concern the installation. For the same reason, for
11
parameters
65
may not be available all the values indicated in
the table.
Below is indicated the table with the parameters
concerning the extended mode. Next to the
number of the parameter is indicated the standard
production value.
standard
production value
Parameter description
function associated with the value 00
function associated with values within 01 and 15
a2
.
12
33
34
40
41
,
,
,
,
,
00
; only by setting the
a2
43
44
,
,
and
11
12
,
,
01
15
and
,
; the maximum
31