Error acknowledgement
The different options available for error acknowledgement are described below.
Manual (Reset button)
Press the Reset button on the front of the device.
If the Reset button is held for longer than approx. 2 s, the device switches back to the error
state.
Manual (remote acknowledgement via bus)
A manual reset can be performed via the bus. See also "Cyclic output data".
Automatic (parameterisation via bus)
When you parameterise this function, the device will automatically acknowledge motor overload
protection activations after 20 minutes.
Feedback
As soon as the device detects an error or indicates that there is a message, this information can
be queried via the bus
1.

7. Replacing fuses

The fuses are rated such that they only need to
be replaced after damage.
Power outages or the switch-off of fuses will be
signalled as a phase failure when the device is
operated (PWR + Err flash and L or R light up).
3.
2.
4.
5.
Revision 1, dated 01/2021
13