PROBE READING MANUAL PRINTING: together with TSP printing terminal
CAUTION: This function is only active if parameter L2=1
Hold the key menu pressed for over 3 seconds to gain access to the
quick-access function.
The display shows the first smart function option.
It blinks at high frequency.
Use the up and down keys to display the function [Prt].
Press the key on/sby/enter to confirm your selection and activate/de-
activate the function.
You can leave the programming phase by waiting for 30 seconds without operating on the
card, or pressing
In both cases, there you will hear 3 consecutive, short beeps and the display will
temporarily show [ESC].
CAUTION: This function is only active if parameter L2=2
Insert the USB flash drive in the port on the control panel.
Press the menu key until the [Def] or [ndF] function flashes on the
display.
Use the up and down keys to display the function [dLo].
Press the on/sby/enter button to activate the data download function on
the USB pendrive.
During the operation, the display will show "dLo" in steady mode.
At the end of data download, the output is signalled by 3 short
consecutive beeps and by the temporary appearance on the display of
the label [ESC].
The display permanently shows the temperature read by the cell probe.
It is advisable to delete data after the download has been completed.
for 5 seconds.
DOWNLOAD DATA HACCP ON USB PENDRIVE
(only for products with standard USB port)
22