You can leave the programming phase by waiting for 30 seconds without operating on the
card, or pressing
In both cases, there you will hear 3 consecutive, short beeps and the display will
temporarily show [ESC].
Par
/1
Room probe calibration (the parameter is expressed in eighths of degree)
/2
evaporator probe activation (0=off;1=on)
/3
condenser probe activation (0=off; 1=on)
/8
temperature measurement unit (0= degrees farenheit, 1=degrees celsius
/9
aux. output setting : 0 = door resist.; 1 = light com.
/A
door resist. activation setpoint (only if /9 =0)
PARAMETER CONFIGUTATION
Hold the key menu pressed for over 3 seconds to gain access to the
quick-access function.
The display shows the first smart function option.
It blinks at high frequency.
Use the up and down keys to display the function [Par].
Press the on/sby/enter key to enter the parameter configuration mode.
Enter the password to gain access.
The display shows the password setting mode [00]
Use the up and down keys to select the password "65"
Press the on/sby/enter key to confirm your selection.
If the password is correct, the display shows the first parameter in the
configuration list.
Use the up and down keys to scroll the controller parameters
Press the on/sby/enter key to confirm your selection.
Use the keys up and down to select the new value
Press the on/sby/enter key to confirm your selection.
for 5 seconds.
PARAMETERS OF CONFIGURATION
Description
MEASUREMENT INPUTS
25
U.M.
min
MAX
°C
-55
+99
-
0
1
-
0
1
-
0
1
-
0
2
°C
-55
+99