INVERTING THE PANEL COLD STORE DOOR
Panel cold stores are supplied with doors opening to the right.
To rehinge to the left, follow the steps below:
•
Rotate the instrument panel on the side heads removing the lower side screws.
•
Remove the door from hinges A while pulling upward.
•
Remove the two hinges A by means of a suitable tool.
•
Reinstall the two hinges A onto the opposite side using the prearranged holes.
•
Remove gasket C and adapt it on the opposite side of the door.
•
Rotate the door hinges B on their axis.
•
Replace the door on hinges A.
•
Move the micro located on the control panel to the opposite side, using the pre-
arranged holes.
•
Replace the instrument panel inserting the screws.
REFRIGERANT MATERIAL SAFETY DATA SHEET
1) R134a
GWP = 1300
ODP = 0
R404A: fluid components
• trifluoroethane
• pentafluoroethane
• tetrafluoroethane
GWP = 3922
ODP = 0
(HFC 143a)
52%
(HFC 125)
44%
(HFC 134a)
36