Remote Control; Troubleshooting - STEINEL PROFESSIONAL IR Quattro DALI Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Parallel-connected Configurations
When using several detectors, they must be connected to the same phase!
k
14
Master/master
The "P" input provides the capabil-
ity of extending the zone move-
ment is detected in.

Remote Control

Using the remote control (option-
al), functions can be conveniently
activated from the floor.

Troubleshooting

Malfunction
Light does not switch 'ON'
Light does not switch 'OFF'
Sensor switches 'OFF' in spite of
persons being present
It is not possible to wire two DALI
power supply units through the "P"
input as the DALI version only pro-
vides one input for "P". It is only
possible to extend the detection
Presence Control remote control
unit:
Service remote control RC 3,
EAN No.: 4007841 000387
User remote control RC 5,
EAN No.: 4007841 592806
Cause
í No supply voltage
í Lux setting too low
í No motion detection
í Lux setting too high
í Stay-'ON' time running out
í Interference from sources
of heat, e.g.: fan heater,
open doors and windows,
pets, light bulb/halogen
floodlight, moving objects
(IR Quattro)
í Stay-'ON' time too short
í Light-level threshold too low
- 24 -
zone with a Presence Control PRO
COM1/COM2 or DIM version.
Remedy
í Check supply voltage
í Slowly increase lux setting
until light switches 'ON'
í Ensure unobstructed sensor
vision
í Check detection zone
í Reduce lux setting
í Wait until stay-'ON' time
elapses; reduce stay-'ON'
time if necessary
í Use stickers to mask out
stationary sources of
interference
í Increase stay-'ON' time
í Change light threshold

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ir quattro hd daliHf 360 daliDual hf dali

Tabla de contenido