DSX Touch
9. Maintenance work
EN
(b)
(c)
Strainer
Maintenance work must only be conducted by an authorised professional.
closed
Cleaning and replacing the filter strainer
The cold water connection of this instantaneous water heater is equipped with an inte
grated shutoff valve and a strainer. Soiling of the strainer may reduce the warm water
(a)
output. Clean or replace the strainer as follows:
1. Deenergize the instantaneous water heater (e.g. via deactivating the fuses) and
prevent inadvertent reactivation of them.
open
2. To open the appliance, take off the small face plate, loose the screw behind this
cover and detach the hood.
3. Close the shutoff valve (a) in the cold water connection piece (position "closed").
4. Unscrew the screw plug (b) from the cold water connection piece and take out the
strainer (c).
Note: Residual water can leak
5. The strainer can now be cleaned or re placed.
6. After fitting of the clean strainer tighten the screw plug.
7. Slowly reopen the shutoff valve in the cold water connection piece (posi
tion "open"). Check all connections for leaks.
8. Vent the appliance by carefully opening and closing the affiliated warm water tap
valve several times until air no longer emerges from the pipe.
9. Fit the hood of the appliance. Then switch on the power again (e.g. via activating
the fuses).
Cleaning and replacing the filter strainer if direct connected
The cold water connection of this instantaneous water heater is equipped with a
strainer. Soiling of the strainer may reduce the warm water output. Clean or replace
the strainer as follows:
1. Deenergize the instantaneous water heater (e.g. via deactivating the fuses) and
prevent inadvertent reactivation of them.
2. Close the shutoff valve in the mains water supply of the instantaneous water
heater.
3. To open the appliance, take off the small face plate, loose the screw behind this
cover and detach the hood.
4. Unscrew mains water inlet from connection piece and take out the strainer.
Note: Residual water can leak
5. The strainer can now be cleaned or replaced.
6. After refitting the clean strainer reconnect the mains water inlet to the connection
piece.
7. Slowly reopen the shutoff valve in the mains water supply. Check all connections
for leaks.
8. Vent the appliance by carefully opening and closing the affiliated warm water tap
valve several times until air no longer emerges from the pipe.
9. Fit the hood of the appliance. Then switch on the power again (e.g. via activating
the fuses).
58