4.4 Using the LED lights
The starter is equipped with white LED lighting (Fig. A-8) and red LED
lights (Fig. A-9) indicating alarms with programmable timing.
To switch on the LED lighting (Fig. A-8), press button
will appear on the display. To enable the red alarm indicator (Fig.
A-9), press button
again; the symbol
the display. Press button
from those available; continue pressing to return to the initial status
with all the lights o .
In order to prevent the starter unit Li battery from discharging, if the
button
is selected accidentally, the white lighting will switch o
automatically after 2 hours.
5. CHARGING
Important! To achieve maximum battery performance, always
charge before use, then after every time it is used and, in any case,
at least every 3 months.
The status of the starter Li battery is indicated on the display by the
illumination of horizontal bars on icon
When icon
lights up on the display, this warns the user to charge
the Li battery as soon as possible.
5.1 Charging with 100Vac - 240Vac 50/60Hz
ATTENTION! Use the supplied power supply adapter only!
- Insert the relative output plug into the charger jack socket (Fig. A-4).
- Insert the power supply adapter plug (Fig. A-3) into a 230Vac socket
or other compatible with the network voltage (100 Vac - 240Vac
50/60Hz).
- During the charge process the horizontal bars on icon
progressively and dynamically and the charge icon
- The starter is tted with a control device to prevent overcharging the
battery and power unit.
- When fully charged, icon
- Disconnect the power cable plug (Fig. A-3) from the mains socket.
- Disconnect the power cable plug (Fig. A-3) from the charger jack
socket (Fig. A-4).
5.2 Charging via the µUSB port
It is also possible to charge the battery via any 5V power source using a
USB-µUSB cable connection, using the µUSB port (Fig. A-5).

6. ALARMS AND WARNINGS

Symbols and messages are used to indicate function anomalies,
incorrect connections of cable clamps, critical battery conditions etc.
on the display.
6.1 ALARMS
- Display icon
ON plus message A.01 on the display
Starter with short-circuit cables or inverted polarity; disconnect the
output cables.
- Display icon
ON plus message A.02 on the display
Battery voltage incompatible with that selected by the operator;
select the correct setting for the connected battery or leave the
starter automatic selection enabled.
With the exclusive 12V model, it indicates that the battery voltage is
not compatible and must be disconnected.
- Display icon
ON plus message A.03 on the display
Lithium battery in unbalanced charge conditions, it is not possible to
use the starter in START mode; Charge the battery.
; the symbol
will appear on
repeatedly to select the timing option
.
appears.
will disappear and icon
will be full.
- Display icons
, lithium battery heat alarm. Battery temperature is too
high, it is not possible to use the starter in START mode. Wait for it to
cool down.
- Display icon
External battery voltage too high, it is not possible to use the starter
in START mode; the engine on the vehicle is probably already
running.
- Display icon
Lithium battery cells are excessively unbalanced, it is not possible to
use the starter in START mode;
Contact the service centre.
- Display icon
.
immediately.
If A.07 persists even 10 hours after the start of charging,
interrupt charging and contact the support centre.
- Display icon
Starter relay damaged.
6.2 WARNINGS
- Display icon
heating unit before starting the vehicle.
- Display icon
recommended.
- Display icon
the USB port (Fig. A-7); Disconnect the USB cable port.
light up
- Display icon
the Jack plug output (Fig. A-7); Disconnect the JACK cable output.
7. DISPOSING OF THE STARTER BATTERY
When the starter battery is completely run down it should be sent to
a re-cycling facility. In some Countries this is mandatory. Contact the
local special refuse authority for information on recycling.
explosion. Before disposing of the battery, apply insulating tape to
the bare terminals to prevent shorting. Do not expose the battery to
intense heat or re as this could cause an explosion.
SPECIFICATIONS (mod. 2012):
Type of battery:
- Rechargeable factory-sealed lithium-polymer battery.
Battery capacity:
- 15000 mAh
Start current:
12V
.
- 600A
- (2500A peak)
Starter cables:
- Polarised terminals.
.
- Copper.
- Diameter 16mm
- Length 300mm
- PVC insulated.
Light:
- White LED.
- Red LED.
.
Output sockets:
- 5V - 2.1A USB port
- 12V, 16V, 19V (programmable) - 3.5A output
Input sockets
- 7 -
and
ON plus message A.04 on the display
ON plus message A.05 on the display
ON plus message A.06 on the display
ON plus message A.07 on the display
Lithium
cells
excessively
ON plus message A.08 on the display
blinking. It is recommended to enable the battery
ON. Lithium cells discharged, charging
blinking. Excessive absorption (over 2.1A) from
blinking. Excessive absorption (over 3.5A) from
WARNING: Do not burn the battery
to dispose of it. This could cause an
2
(5 AWG).
.
.
discharged,
charge
.

Publicidad

Tabla de contenido
loading

Tabla de contenido