10. PRODUCT SPECIFICATION
EN
Display :
Technology:
Classification :
Measurement range:
Accuracy
:
Memory :
Power supply:
Battery life:
Accessories:
Operation conditions:
Transport/Storage conditions:
Weight of main unit :
External dimensions:
NOTE:
Specifications are subject to change without prior notice.
32
100042_MEDEL CHECK USER MANUAL_ ALL LANGUAGES.indd 32-33
LCD digital display
Oscillometric method
Internally powered equipment, with type
BF applied part
Pressure : 30 to 280 mmHg
Heart rate : 40 to 199 times/minute
Pressure : +/- 3 mmHg
Heart rate : +/- 5%
Storing 60 memories (Systolic / Diastolic
pressure, Heart beat) for each user (2)
4 AA 1.5V (batteries)
For approx. 300 measurements, depending on
levels of blood pressure and pump pressure
Universal cuff circum. 22 - 42cm
Cuff pressure: 0 to 300 mmHg
Temperature : +10°C to +40° C;
Relative Humidity: 10 - 85%
pressure: 80 to 105 kPa
Temperature : -20°C to +60°C ;
Relative Humidity : 10 - 95%
pressure: 80 to 105 kPa
320 g (without batteries)
185 X 100 X 55 mm
10. WARRANTY CONDITIONS
•
The device is covered by a 5-year warranty from date of purchase for any
defects in the design or in the material used.
•
The warranty consists in the replacement and/or repair free of charge of
originally detective components.
•
The warranty does not cover the accessories supplied with the equipment
and those parts subject to normal wear and tear.
•
The equipment must be repaired by authorized technical service centres
only.
•
The equipment must be sent to the authorized technical service centre for
repair within 8 days after the defect is noticed.
•
The transport costs for the equipment are at user's charge. Any repair out
of the warranty conditions are at user's charge.
•
The warranty does not cover failures resulting from misuse, abuse of the
product or in case the damage is not due to manufacturer's liability (acci-
dental fall, rough transportation, etc...)
•
The warranty does not involve any compensation for any kind of damages
to persons or things, either direct or indirect, occurred when the equipment
is not operating.
•
The warranty is valid from the date of purchase certified by the ticket or the
invoice which have to be peremptorily attached to the warranty coupon.
•
The lack of warranty coupon properly filled in and validated by a certifica-
tion of purchase voids the warranty.
COUPON TO BE RETURNED IN CASE OF REPAIRS
THE WARRANTY IS VALID ONLY IF ACCOMPANIED BY THE TICKET/INVOICE
Product type:
Model:
Serial No.:
Date of purchase:
BUYER'S DATA
Name:
Address:
Telephone:
Defect description:
Signature for acceptance of the above mentioned warranty conditions
EN
33
28/06/2017 10:31:31