SICK WS14-2 Manual De Operación página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
3
COMMISSIONING
2
operating reserve
1000
100
10
Sensing range
1
m
5
10
(feet)
(16.40)
(32.81)
Distance in m (feet)
Image: H
2
Mount sensors (sender and receiver) using suitable mounting brackets (see the
SICK range of accessories). Align the sender and receiver with each other.
Note the sensor's maximum permissible tightening torque of 1.3 Nm.
3
The sensors must be connected in a voltage-free state (U
in the graphics [B] must be observed, depending on the connection type:
Male connector connection: pin assignment
Cable: core color
Technical data and connection diagrams (figure B) starting on page 55.
Only apply voltage/switch on the power supply (U
tions have been established. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching outputs Q and /Q (according to Graphic B):
WS/WE14-2P / K (PNP: load -> M)
WS/WE14-2N / L (NPN: load -> L+)
TI / Test = test input (see Additional functions)
4
WS/WE14-2Xx3x: Align the sender with the receiver. Select the position so that the
red emitted light beam hits the receiver. Tip: Use white paper or a reflector as an
alignment aid. The sender must have a clear view of the receiver, with no object in
the path of the beam [see E]. You must ensure that the optical openings (front
screen) of the sensors are completely clear.
WS/WE14-2Xx1x: Align the sender with the receiver. Select the position so that the
infrared light (not visible) hits the receiver. The correct alignment can only be detec‐
ted via the LED indicators. Please refer to Graphics C and E in relation to this. The
sender must have a clear view of the receiver, and no object may be in the optical
path. You must ensure that the optical openings (front screen) of the sensors are
completely clear.
Image: E
5
Sensor which it is not possible to set (WS/WE14-2Xxx0): The sensor is set and
ready for operation.
15
(49.21)
v
= 0 V). The information
v
> 0 V) once all electrical connec‐
8016167.YFQ1 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

We14-2

Tabla de contenido