10 MALFUNCTIONS
WARNING: The machine must be isolated from the power supply before attempting any work on it.
Problem
The machine will not start
The hydraulic power pack starts up but the
head will not rise
The green light flashes quickly
Machine lacks power
The head rises but the knives do not
extend
Oil on the floor
Check the main power supply and the power supply to
the motor.
Check whether the thermal cut-out has tripped.
Switch 2 phases at the machine plug.
Activate the emergency stop
Check oil level. The level must be between 4 and 5 cm
from the top edge.
Contact your technician.
Contact your technician.
Should the problem persist, please contact your technician.
Check
13
English