3.5 PRE-INSTALLATION WORKS
The igure shows an example of an automation system, constructed using Nice components.
5
A
A Photocells
B Photocells on column
C Key selector
D Boom gate cubicle
TECHNICAL SPECIFICATIONS OF ELECTRICAL CABLES
Identiication
Cable characteristics
no.
GEARMOTOR POWER SUPPLY cable
1 cable 3 x 1.5 mm
1
Maximum length 30 m [note 1]
BLUEBUS cable
1 cable 2 x 0.5 mm
2
Maximum length 20 m [note 2]
KEY SELECTOR cable
2 cables 2 x 0.25 mm
3
Maximum length 30 m
OPEN INPUT cable
1 cable 2 x 0.25 mm
Maximum length 30 m
CLOSE INPUT cable
2 x 0.25 mm
Maximum length 30 m
WARNING LIGHT cable [note 4]
1 cable 2 x 0.5 mm
Maximum length 30 m
ANTENNA cable
Other cables
1 x RG58-type shielded cable
Maximum length 15 m; recommended < 5 m
OPEN BOOM INDICATOR cable [note 4]
1 cable 2 x 0.5 mm
Maximum length 30 m
BOOM LIGHTS cable [note 4]
MASTER/SLAVE cable
1 cable 3 x 1 mm
Maximum length 20 m
C
B
2
2
2
[note 3]
2
2
2
2
2
2
A
3
These above-mentioned components are positioned according
to a typical standard layout. Using the layout in "Figure 5" as
a reference, deine the approximate position in which each
component of the system will be installed.
Note 1 If the power supply cable is longer than 30 m, a cable
Table 3
with larger cross-sectional area (3 x 2.5 mm
used and a safety earthing system must be installed
near the automation.
Note 2 If the BlueBus cable is longer then 20 m, up to maximum
40 m, it is necessary to use a cable with a greater cross-
sectional area (2 x 1 mm
Note 3 These two cables can be replaced by a single 4 x 0.5
mm
cable.
2
Note 4 Before making the connection, verify that the output is
programmed on the basis of the device to be connected
(refer to the chapter "PROGRAMMING").
a
The cables used must be suited to the type of
environment of the installation site.
a
When laying the pipes for routing the electrical
cables, take into account that any water deposits in
the junction boxes may cause the connection pipes
to form condensate inside the control unit, thus
damaging the electronic circuits.
a
Before proceeding with the installation, prepare
the required electrical cables by referring to
"Figure 5" and to that stated in the "TECHNICAL
SPECIFICATIONS" chapter.
B
D
2
1
2
).
) must be
2