Control De La Unidad Midi - Roland SP-808EX Manual Del Usuario

E-mix studio
Ocultar thumbs Ver también para SP-808EX:
Tabla de contenido

Publicidad

Apéndices
I Mensaje System Exclusive
Status
Data Bytes
F0H
iiH,ddH, ..., eeH
Byte
Description
F0H
Status of System Exclusive Message
iiH
Manufacturer ID
41H Roland's Manufacturer ID
7EH Universal Non Realtime Message
7FH Universal Realtime Message
ddH
Data: 00H--7FH (0--127)
|
|
eeH
Data
F7H
EOX (End of System Exclusive Message)
❍ About Model ID
For Data Request (RQ1) and Data Set (DT1), SP-808EX uses 00H 0FH as a Model ID.
G Universal System Exclusive Message
❍ INQUIRY MESSAGE
✧ Identity Request
Status
Data Bytes
F0H
7EH, Dev, 06H, 01H
Byte
Description
F0H
Status of System Exclusive Message
7EH
Universal System Exclusive Message Non Realtime Header
Dev
Device ID (10H or 7FH)
06H
General Information (sub ID #1)
01H
Identify Request (sub ID #2)
F7H
EOX (End of System Exclusive Message)
The message is used to request the particular information of the SP-808EX.
The SP-808EX does not transmit the message.
If the SP-808EX received the message and the device ID of the message is same as 10H or
7FH, the SP-808EX transmits the following Identity Reply message.
✧ MIDI Machine Control Commands
Status
Data Bytes
F0H
7FH, Dev, 06H, aaH, ..., bb
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (10H or 7FH)
06H
MMC Command Message
aaH
Command
|
|
bbH
Command
F7H
EOX (End of System Exclusive Message)
* See "2. MIDI Machine Control" section.
✧ MIDI Machine Control Responses
Status
Data Bytes
F0H
7FH, Dev, 07H, aaH, ..., bb
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (10H or 7FH)
07H
MMC Response Message
aaH
Response
|
|
bbH
Response
F7H
EOX (End of System Exclusive Message)
* See "2. MIDI Machine Control" section.
199
Status
F7H
Status
F7H
Status
F7H
Status
F7H
G Data Transfer (RQ1, DT1)
❍ Data Request (RQ1)
Status
Data Bytes
F0H
41H, Dev, 00H, 0EH, 11H, aaH, bbH, ccH, ssH, ssH, ssH, Sum F7H
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 2BH
ModelID (SP-808EX)
11H
Command ID (RQ1)
aaH
Address MSB
bbH
Address
ccH
Address LSB
ssH
Size MSB
ssH
Size
ssH
Size LSB
Sum
Checksum
F7H
EOX (End of System Exclusive Message)
The message is used to request data to the SP-808EX.
The SP-808EX does not transmit this message.
The SP-808EX transmits the requested data using Data Set(DT1) under following condition
when it received the message.
1. The requested address correspond to the specified parameter base address of the SP-808EX.
2. The requested size is over 1 byte.
❍ Data Set (DT1)
Status
Data Bytes
F0H
41H, Dev, 00H, 0EH, 12H, aaH, bbH, ccH, ddH, ..., eeH, Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 2BH
Model ID (SP-808EX)
12H
Command ID (DT1)
aaH
Address MSB
bbH
Address
ccH
Address LSB
ddH
Data
|
|
eeH
Data
Sum
Checksum
F7H
EOX (End of System Exclusive Message)
✧ The message is received under the following condition
If the device ID on the message is same as that of the receive device, and the address on the
message correspond to the specified parameter base address, the received data are stored
from the specified parameter base address.
If the interval of received messages is shorter than 25 msec, the SP-808EX can not work the
receive message procedure correctly.
✧ The message is transmitted under the following condition
When the SP-808EX transmit the data on the requested parameter after receiving the Data
Request message (RQ1).
* See "2. Data Transfer Address Map" for more details of the transfer parameters.

2. Control de la Unidad MIDI

I Detalles del Control de la Unidad MIDI
G STOP (MCS)
Status
Data Bytes
F0H
7FH, Dev, 06H, 01H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (10H or 7FH)
06H
MMC Command Message
01H
STOP (MCS)
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving 10H or 7FH, the
SP-808EX stops immediately.
Status
Status
F7H
Status
F7H

Publicidad

Tabla de contenido
loading

Tabla de contenido