aquatermic inverter Manual Del Usuario página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

[Notes]
① When it is activated, at the WEEKLY TIMER page, it is able to set some week day to "Holiday
release". In this case, the "Weekly timer" in this day is ineffective unless it is set to "Effective"
manually.
② This setting will be memorized upon power failure.
2.2.11 Disinfection
This function is intended to sanitize the water tank by raising the water temperature to 70°C
under which the legionella will die immediately. When this function is activated, the sanitation data
and start time is configurable.
[Operation Instructions]
1. At the FUNCTION page, locate "Disinfection", and then access to the DISINFECTION setting
page by pressing the OK key
2. At the DISINFECTION setting page, select "Set clock", "Set week" or "Set temp" through the
Left/Right key
.
3. When the mode setting is finished, then by pressing "Save", a pop-up window will pop up
to remind if you are determined to save this setting. If so, press the OK key
Cancel key
to not save this setting.
4. When the setting is saved, the control then will back to the FUNCTION page and the cursor
will be where the "Disinfection" is, then by the Up/Down key
Disinfection temperature
[Notes]
① It can be activated only when the "Water tank" is set to "With".
② It can be set to "On" or "Off" no matter if the unit is in operation or not
③ When "Disinfection" is set to "On", if you intend to set the "Emergen. mode", "Holiday
mode", "Floor Debug", then a window will pop up, warning "Please disable the Disinfection
Mode!".
④ It can be set to "On" or "Off" no matter if the unit is in operation or not, and "Hot water" mode
always takes precedence.
.
and then modify the corresponding setting through the Up/Down key
Name
Set temp.
Name
Default
70°C
10
Operation Instructions
. If not, press the
, it can be set to "On" or "Off".
Range
45°C~70°C