Operation Instructions
No.
Full Name
Running mode
1
setting
2
Control state
3
Fast hot water
Water out
4
temperature
control
5
Cool+hot water
6
Heat+hot water
7
Quiet mode
8
Quiet timer
Weather-
9
dependent
mode
10
Holiday release
11
Disinfection
12
Weekly timer
13
Clock timer
Temperature
14
timer
15
Solar kit-timer
16
Floor debug
Emergency
17
mode
18
Holiday mode
19
Thermostat
20
Assistant heater
21
Other heater
22
Chassis heater
Tank heater
23
running
Function Settings
Displayed Name
Mode
Cool+Hot water
Heat+Hot water
T-water out /
Ctrl. state
Fast hot water
High temp.
T-water ctrl.
/Normal temp.
Cool+hot water
Cool/Hot water
Heat+hot water
Heat/Hot water
Quiet mode
Quiet timer
Weatherdepend
Holiday release
Disinfection
Weekly timer
Clock timer
Temp. timer
Solar timer
Floor debug
Emergen. mode
Holiday mode
Thermostat
With/Without
Assistant heater
Other heater
With/Without
Chassis heater
Tank heater
Range
Default
Cool
Heat
Hot water
Heat
T-water
T-room
out
On/Off
Off
Normal
temp.
Cool
Heat
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
Without
1/2/Off
1
Without
On/Off
On
On/Off
On
5
Remarks
When the water tank is unavailable,
then only "Cool" and "Heat" are
included in the range.
"T-Room" is available only when
"Remote Sensor" is set to "WITH".
When the water tank is unavailable,
this function will be reserved, and
the LCD will display 'Reserved'.
/
When the water tank is unavailable,
this function will be reserved, and
the LCD will display 'Reserved'.
When the water tank is unavailable,
this function will be reserved, and
the LCD will display 'Reserved'.
/
/
/
/
When the water tank is unavailable,
this function will be reserved, and
the LCD will display 'Reserved'.
/
/
/
When the water tank is unavailable,
this function will be reserved, and
the LCD will display 'Reserved'.
/
/
/
/
/
/
/
If the water tank is available, this
function can be configured; if not,
this function will be reserved. When
"Tank heater" is set to be "Off"
but the solar kit is available, the
tank temperature can be adjusted
normally; when "Tank heater" is "Off"
and the solar kit is unavailable, then
the upper limit of tank temperature
is fixed to be 50°C.