Operation Instructions
① It will be memorized upon power failure.
② When it is set to be "with", the water temperature is not allowed to be set to "High temp."
2.2.30 Radia config
It can be configured to be "With" or "Without" based on the actual condition.
[Operation Instructions]
Go to the FUNCTION page and locate "Radia config", then, configure it through the Up/Down
key
, "With" or "Without".
[Notes]
① It will be memorized upon power failure.
② When it is set to "with", the water temperature is defaulted to be "High temp."
2.2.31 FCU
It can be configured to be "With" or "Without" based on the actual condition.
[Operation Instructions]
Go to the FUNCTION page and locate "FCU", then, configure it through the Up/Down key
, "With" or "Without".
[Notes]
●It will be memorized upon power failure.
2.2.32 Remote Sensor
It can be configured to be "With" or "Without" based on the actual condition.
[Operation Instructions]
Go to the FUNCTION page and locate "Remote sensor", then, configure it through the Up/Down
key
, "With" or "Without".
[Notes]
① It will be memorized upon power failure.
② "T-room ctrl" can be selected only when the Remote Sensor is set to "With".
2.2.33 Air removal
This function is intended to expel air inside the water system with only the water pump in
operation when installation of the unit is finished.
[Operation Instructions]
Go to the FUNCTION page and locate "Air removal", then, configure it through the Up/Down
key
, "On" or "Off".
[Notes]
① It will not be memorized upon power failure.
② It can be set only when the unit is turned off.
2.2.34 Address
It is used to identify the unit in use in the central control system.
[Operation Instructions]
Go to the FUNCTION page and locate "Address", then, configure it through the Up/Down key
21