Balluff BTL7-A/C/E/G5 Serie Manual Del Usuario página 56

Ocultar thumbs Ver también para BTL7-A/C/E/G5 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123
BTL7-A/C/E/G5_ _-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Transducer - Rod Style
8
Adjusting (continued)
Set end point
► Bring magnet to the new end point.
► Activate
b
for at least 2 s.
⇒ The new end point is set with the last valid
end value.
Adjust end value
► The end value can be changed using
gradient of the curve changes
(see page 17).
► End calibration procedure: Briefly activate
simultaneously (< 1 s).
⇒ Set position value is saved.
End adjustment
► Briefly activate
a
and
⇒ The current position value is displayed once the
buttons are released.
Any of the individual steps for settings can be
selected. The adjustment process can be
ended at any time.
20
english
a
b
and
. The
a
b
and
b
simultaneously (< 1 s).
b
> 2 s
a
a
b
b
a
b
< 1 s
a
b
< 1 s
Ignition protection "d"
Flameproof enclosure
Displayed values (example)
At 0 to 10 V
At 4 to 20 mA
9.89 V
19.13 mA
10.00 V
20.00 mA
10.00 V
20.00 mA
8.00 V
16.80 mA
2.00 V
6.00 mA
8.00 V
16.80 mA
10.50 V
3.60 mA
7.63 V
18.56 mA

Publicidad

Tabla de contenido
loading

Tabla de contenido