BTL7-A/C/E/G5_ _-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Transducer - Rod Style
9

Resetting all values (reset)

NOTICE
Interference in function
Resetting the values while the system is running may
result in malfunctions.
► Stop the system before performing the reset.
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
Activate reset
► Simultaneously activate
a
Reset
a
► Simultaneously activate
After activation:
⇒ All values are reset.
⇒ Current position value is displayed.
⇒ Reset is deactivated.
Abort reset
Resetting can be aborted without any changes
being saved after the Activate reset step.
► Briefly activate
a
b
and
⇒ Current position value is displayed.
www.balluff.com
b
and
for at least 4 s.
b
and
for at least 4 s.
simultaneously (< 1 s).
a
b
> 4 s
a
b
> 4 s
a
b
< 1 s
Ignition protection "d"
Flameproof enclosure
Displayed values (example)
At 0 to 10 V
At 4 to 20 mA
5.39 V
9.15 mA
10.50 V
3.60 mA
0.00 V
4.00 mA
9.89 V
19.13 mA
english
21