FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
TROUBLE
1. Fan will not start. 1 . Fuse or circuit breaker blown .
2 . Loose power line connections to the fan .
3 . Fan/Light wall control is OFF .
4 . Wall control is not programmed .
2. Fan sounds
1 . Blades not attached to fan .
noisy.
2 . Screws securing fan flange/blade assemblies
to the motor hub are loose .
3 . Screws holding blades to flanges are loose .
4 . The shade is loose .
5 . Hanger bracket and/or ceiling outlet box is
not securely fastened .
3. Fan wobbles
1 . Screws securing fan flange/blade assemblies
excessively.
to motor are loose .
2 . Set screw in motor coupler is loose .
3 . Fan blades out of balance .
4 . Hanger bracket and/or ceiling outlet box is
not securely fastened .
5 . Set screw in hanger ball/downrod assembly
is loose .
6 . Screws securing fan motor to the motor hub
are loose .
15. Troubleshooting
!
PROBABLE CAUSE
PROBABLE CAUSE
WARNING
1 . Check main and branch circuit fuses or circuit breakers .
Make sure main power is turned OFF.
2 . Check line power connections to fan .
3 . Turn ON fan/light wall control .
4 . Program the wall control and receiver per the Owner's
Manual instructions .
1 . Attach blades to fan before operating .
Make sure main power is turned OFF.
2 . Check to make sure the screws which attach the
flange/blade assemblies to the motor hub are tight .
3 . Tighten screws securely .
4 . Tighten the shade securely .
5 . Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box .
1 . Check to be sure screws which attach the fan
flange/blade assemblies to the motor are tight .
2 . Raise coupler cover and tighten the set screw securely .
3 . Interchanging an adjacent (side by-side) blade pair can
redistribute the weight and result in smoother operation .
Or use supplied balancing kit to balance blades .
4 . Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box .
5 . Tighten the set screw in the hanger ball/downrod
assembly .
6 . Check to be sure the screws which attach the
motor to the motor hub are tight .
30
SUGGESTED REMEDY
SUG
WARNING
!
WARNING
!
U.L. Model No.: CF4802 and CF4502