WS-400 Series2 [BASE & CLEAR] - LS-400 Series2 GRAVITY SPRAY GUNS
EN
19-2 WS-400 SR2 | LS-400 SR2 AIR CAP - FLUID NOZZLE + FLUID NEEDLE COMBINATION
FLUID NOZZLE + FLUID NEEDLE SET
MODEL
CODE
WS-400 BASE
WS-400-OBS.0
93008930
WS-400-OBS
93008340
WS-400-OBS.1
93008990
WS-400-BFS
93018150
WS-400 CLEAR
WS-400-12H03
93009140
Ws-400-13H03
93009060
Ws-400-14H03
93009160
Ws-400-15H03
93009180
LS-400 ET
LS-400-1206
93008160
LS-400-1306
93008070
LS-400-1406
93008180
LS-400-1506
93008200
LS-400 ETS
LS-400-12S06
93008230
LS-400-13S06
93008250
LS-400-14S06
93008270
LS-400-15S06
93008290
14
AIR CAP SET
Nozzle Mark
CODE
Air Cap Mark
OBS-0
OBS
93008310
WS-400-02-OBS
OBS+1
BF-S
93018140
WS-400-03-BF
12 HD
13 HD
93009030
WS-400-03
14 HD
15 HD
12 ET
13 ET
93008030
LS-400-06
14 ET
15 ET
12 ETS
13 ETS
93008030
LS-400-06
14 ETS
15 ETS
WS-400 Series2 [BASE & CLEAR] - LS-400 Series2 GRAVITY SPRAY GUNS
20. TROUBLESHOOTING
PROBLEM
GUN DOES NOT SPRAY
Fluid adj. knob (13) closed.
Tip hole of nozzle (2) obstructed.
Deposit of paint between the fluid needle (2-1) and the needle
packing set (3).
Paint filter obstructed.
Non drip obstructed.
INTERMITTENT SPRAY PATTERN
Air leaks from fluid nozzle (2).
Air leaks from fluid needle packing (3).
Air leaks from cup joint.
Dirty inside air cap set (1).
DEFECTIVE SPRAY PATTERN
Dirty nozzle (2) or air cap set (1).
Nozzle (2) or air cap (1) has been damaged.
Fluid nozzle (2) is loose.
Paint viscosity too high or too low.
Fluid output too high or too low.
LEAKING
Fluid nozzle (2), needle set (2-1) or gun body, dirty, damaged
or worn on seat.
Dirty inside air cap set (1).
Loose fluid adj. knob (13).
Fluid needle spring set (11) is worn.
Loose fluid nozzle set (2).
Needle packing set (3) loose, too tight, dirty or worn.
AIR LEAKS FROM AIR CAP
Air valve (8), air valve seat (7) or air valve spring (9) dirty or
damaged.
Air valve seat set O'ring (7-1) damaged or worn.
DIGITAL PRESSURE GAUGE DOES NOT WORK
The pressure display doesn't indicate any pressure value.
The air pressure indicated on pressure display is not correct.
20.1 INSPECTION AND REPLACEMENT STANDARD
WHERE TO INSPECT
Each hole passage of air cap (1) and fluid
Replace if it is crushed or deformed.
nozzle (2).
Packing and O ring.
Replace if it is deformed or worn out.
Leakage from seat section between fluid
Replace them if leakage does not stop after fully cleaning fluid nozzle
nozzle (2) and fluid needle set (2-1).
(2) and fluid needle set (2-1).
If you replace fluid nozzle (2) or fluid needle set (2-1) only, fully match
them and confirm that there is no leakage.
EN
REMEDY
Check and adjust it.
Check and clean it.
Check and clean it.
Check and clean it.
Check and clean it.
Check, clean or replace.
Tighten.
Tighten.
Clean.
Clean carefully.
Replace if damaged.
Tighten.
Dilute paint or increase viscosity.
Adjust fluid adj. knob (13) to reduce
or increase.
Check, clean or replace.
Clean.
Adjust.
Replace.
Tighten.
Adjust, clean or replace.
Clean or replace if necessary.
Replace.
Replace the battery.
Remove and re-insert the battery for
automatic calibration.