Descargar Imprimir esta página

Technical Data; Ambient Condition; Detection Range/Measuring Range; Electrical Data - Balluff BTL BNC 00 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL BNC 00 Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 93
BTL BNC_ 00- _ _ _ _ -C15A _ _ _0- _ _ _ _ _ _ / BTL ZNC_ 00- _ _ _ _ -C15A _ _ _0- _ _ _ _ _ _
Magnetostrictive Linear Position Sensor – Rod Style
9

Technical data

The specifications are typical values for
BTL BNC_ 00- _ _ _ _ -C15A _ _ _0- _ _ _ _ _ _ and
BTL ZNC_ 00- _ _ _ _ -C15A _ _ _0- _ _ _ _ _ _ at 24 V DC,
room temperature and a measuring length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R or BTL-P-1014-2R magnet.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1

Ambient condition

Ambient temperature
Storage temperature
Relative humidity
Operating pressure
Maximum pressure
Typ. temperature coefficient
1)
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock per
EN 60068-2-27
2), 3)
Vibration per EN 60068-2-6
2), 3)
Protection per IEC 60529 (when
threaded together)
9.2

Detection range/Measuring range

Measuring length
Analog resolution
...-C15AA/-C15A1...
...-C15AE/-C15A5...
Repeat accuracy
with measuring length ≤ 500 mm
with measuring length > 500 mm
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Linearity deviation
4)
with measuring length ≤ 500 mm
with measuring length > 500 mm
Detectable speed
www.balluff.com
9.3
Operating voltage U
Current draw (at 24 V DC)
Power consumption
−40...+85 °C
−40...+100 °C
≤ 90%, non-con-
densing
≤ 450 bar
Overvoltage protection
750 bar
(10 × 1 min)
Voltage-proof up to (GND – Housing)
≤ 30 ppm/K
...-C15AA/-C15A1...
100 g/6 ms
...-C15AE/-C15A5...
50 g/2 ms
12 g, 10
9.4
...2000 Hz
Short circuit protection
IP67, IP69K
Protected against polarity
reversal
25...4000 mm
Measuring length 500 mm, magnet in the middle of the measuring range
1)
2)
Individual specifications as per Balluff standard
183 μV / ≥ 4 μm
Resonant frequencies excluded
3)
351 nA / ≥ 4 μm
Configuration for one magnet
4)
A prerequisite is that no current can flow between GND and 0 V in the
5)
event of polarity reversal.
≤ ±10 µm
≤ ±0.002% FS
1000 Hz
500 Hz
250 Hz
±60 μm
±0.012% FS
≤ 10 m/s

Electrical data

b
...-C15AA_20-.../...-C15A1_20-...
...-C15AA_40-.../...-C15A1_40-...
...-C15AA_B0-.../...-C15A1_B0-... ≤ 80 mA
...-C15AA_C0-.../...-C15A1_C0-... ≤ 80 mA
...-C15AE010-.../...-C15A5010-...
...-C15AE_B0-.../...-C15A5_B0-... ≤ 110 mA
...-C15AE_C0-.../...-C15A5_C0-... ≤ 110 mA
...-C15AA_20-.../...-C15A1_20-...
...-C15AA_40-.../...-C15A1_40-...
...-C15AA_B0-.../...-C15A1_B0-... ≤ 2.0 W
...-C15AA_C0-.../...-C15A1_C0-... ≤ 2.0 W
...-C15AE010-.../...-C15A5010-...
...-C15AE_B0-.../...-C15A5_B0-... ≤ 2.7 W
...-C15AE_C0-.../...-C15A5_C0-... ≤ 2.7 W
Output current
Load resistance R
Lc

Electrical Connection

5)
10...30 V DC
≤ 70 mA
≤ 70 mA
≤ 80 mA
≤ 1.7 W
≤ 1.7 W
≤ 2.0 W
U
up to 36 V DC
b
500 V DC
≤ 5 mA
≤ 500 ohm
Signal output to GND
and to 30 V DC
U
up to 30 V DC
b
english