3. Thermal radiation
The thermal effect is due to the absorption of the energy of the blue light in the tissues, during which
the energy is converted into heat. The risk is only with prolonged overdose.
Risk of pain, burning of soft tissues.
4. Fire safety
- Keep the device away from solvents, flammable liquids and powerful heat sources.
- Do not expose to direct sunlight.
- Do not allow liquids and detergents to enter the device, as this may cause a short circuit and fire
or cause potentially dangerous damage.
- If the product emits an odor or smoke – disconnect from the mains, do not attempt to repair it, take
it to a service center.
Risk of fire, explosion and damage.
5. Danger of mechanical moving parts
- To be used in rooms with a horizontal floor surface.
- Assemble the mechanical parts, position them, lock them slowly with care.
- The device must not be used for transporting or moving people or objects.
- The counterweight must be fully screwed in order to avoid falling and injuring people and objects.
- Fix the emitting head well - at an appropriate height and distance to be stable in front of the pa-
tient's teeth during the procedure.
- Do not turn the horizontal arm by force to avoid mechanical shocks with the counterweight or the
bleaching head. In the event of a mechanical shock, if the whitening head is damaged, the use of
the device must not be continued. It must be taken immediately to the company service center.
- To take measures against damage to the human body by mechanical parts (movable and immov-
able), pinching, inertial reinforcement of the counterweight, manipulations with the device to be
performed carefully to avoid injury.
- The movement of the parts of the device without prior unscrewing of the fixators can damage their
locking mechanism. The wheel stoppers, if any, must be released before moving the bleaching
unit.
Risk of mechanical damage to the operator and the patient.
6. Who should not be bleached because of prohibitions and risk of burns
and complications:
- The device should not be used by: pregnant and breastfeeding mothers; patients with severe peri-
odontal pathology, with recessions, dental hyperesthesias and under 17 years of age; patients with
allergies, wounds and infections, fresh scars on the face, skin infections, recently placed dental
implants or surgical procedures in the oral cavity and face, fibral conditions, herpes, bleeding,
bruises, burns, cancer or indications of such on the face and lips cavity, atypical warts in the area of
irradiation, difficult to heal wounds; patients taking painkillers that dull the skin's sensitivity to heat;
persons under the influence of alcohol or narcotics.
- The device can be used only after medical consultation on or by: persons with implanted cardiac
pacemaker; persons suffering from photobiological reactions; persons taking photosensitive drugs;
persons undergoing cataract surgery; persons with retinal diseases; people with allergies; people
who have recently undergone cosmetic surgery on the face or lips, including injections of hyaluron-
ic acid or botox, people with very sensitive skin or dermatitis, etc. If you are taking photosensitizers
or medicines, check the package leaflet and never undergo bleaching procedure if it is indicated