12
IT UK
1 - TECHNICAL SPECIFICATIONS
Control unit
Radio receiver on board
Type
Power supply
N° motors
Motor power supply
Flashing light
Accessories power supply
Photocell input
Edge input
Operating temperature
2 - TECHNICAL SPECIFICATIONS / FUNCTIONS
Ÿ
Blue LED
indicating the operating state of the control unit.
Red LED indicating radio codes learning.
Ÿ
Red LED indicating dip Sw1 state.
Ÿ
Flashing light or courtesy light management.
Ÿ
Key for transmitters programming and learning on board.
Ÿ
2 N.C. photocell and edge inputs.
Ÿ
2 possible operation logics: step - step with stop / dead man.
Ÿ
Programming of pause time (180 s max.) and working time (150 s max).
Ÿ
Programming «BUTTON UP» input as START or ONLY OPENING.
Ÿ
Radio receiver on board, that can store up to 31 keys or transmitters.
Ÿ
3 - INSTALLATION WARNINGS
• Before proceeding with the installation, it is necessary to fit upstream of the system a magnetothermal
differential switch with a max. capacity of 10A. The switch must guarantee an omnipolar separation of the
contacts, with an opening distance of at least 3 mm.
• To avoid any possible interferences, differentiate and always keep separate the power cables (min. section 1 , 5
mm²) from the signal cables (min. section 0,5 mm²).
• Make the connections referring to the following tables and the screen printing on the control unit. Be extremely
careful to connect in series all the devices that must be connected to the same N.C. (normally closed) input
and in parallel all the devices that share the same N.O. (normally open) input. A wrong installation or an
improper use of the product may compromise the safety of the system.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device, if the original
components and accessories suitable for the specific automation are not used.
• At the end of the installation, always carefully check the proper functioning of the system and the devices used.
• This instruction manual addresses people qualified for the installation of "live equipment". Therefore good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
AS07300
868,35 MHz
Electronic control unit for the automation
of a shutter motor
230Vac monophase 50/60 Hz
1
230 Vac 1200W max
230Vac 40W max
12Vac 1,2W max
N.C.
N.C.
-30°C +50°C
SR302
and