Descargar Imprimir esta página

GiBiDi SR302 Instrucciones Para La Instalación página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

16
IT UK
OFF
DIP 7
ON
OFF
DIP 8
MANAGEMENT
ON
8 - TIMES LEARNING
PRELIMINARY WARNINGS:
Values loaded by default:
Ÿ
- Working time: 60 s;
- Pause time : 30 s;
The learning of working time and
Ÿ
Be sure that the shutter is completely closed before making the learning procedure.
Ÿ
• Check the correct position of the limit switch.
PROGRAMMING OF THE AUTOMATIC RECLOSING TIME:
• When the shutter is closed, put DIP2 in ON, then DIP3 in ON
LED DL9 will turn on fixed.
Ÿ
• Give any command (OPEN / CLOSE/ START)
An acoustic signal will show the beginning of pause time counting, LED DL9 will start blinking every second
Ÿ
• After the required time (MAX. 180 s), give any command (OPEN / CLOSE/ START);
A double acoustic signal and LED DL9 turning off will show that the operation has been successful;
Ÿ
Put DIP 3 in OFF
Ÿ
PROGRAMMING OF THE WORKING TIME:
• When the shutter is closed, put DIP2 in OFF, then DIP3 in ON
LED DL9 will turn on fixed.
Ÿ
• Give any command ( OPEN / CLOSE/ START);
The shutter will start the opening phase, LED DL9 will turn off and an acoustic signal will show the beginning of
Ÿ
the opening time counting.
The intervention of a photocell / edge will be irrelevant;
Ÿ
• On reaching the opening limit switch or after any command (OPEN / CLOSE/ START), the motion
will block;
LED DL9 will turn on fixed.
Ÿ
• Give any command ( OPEN / CLOSE/ START)
The shutter will start the closing phase and LED DL9 will turn off .
Ÿ
The intervention of a photocell / edge will temporarly block the counting and the closing manoeuvre of the
Ÿ
shutter, it is necessary to start again from the previous point.
• On reaching the closing limit switch or after any command ( OPEN / CLOSE/ START), the closing motion will
block;
LED Dl9 will turn on fixed and the control unit will emit a double acoustic signal, showing that the
Ÿ
operation has been successful.
Put DIP 3 in OFF.
Ÿ
Put DIP 2 to the original state.
Ÿ
UNUSED
Unused
OPEN command is associated with terminal 14 (the control unit will open but
TERMINALS
won't automatically close,even if the automatic closing is enabled),
13-14
as CLOSE command is associated with terminal 13.
START command is associated with terminal 14, as terminal 13 is disabled.
automatic closing require 2 different procedures.
SR302

Publicidad

loading

Este manual también es adecuado para:

As07300