OPERATING SAFETY
There is a safety device that guarantees correct system operation.
This safety device is triggered whenever, after three consecutive operating cycles (suction) of the motor, no fuel is sucked so the
DOSING UNIT remains empty.
In this case, the safety device interrupts operation, which is no longer reset automatically.
There may be various causes, including the following:
• There is no fuel inside the storage unit
• The piping between the storage unit and the DOSING unit is clogged with fuel
• The pipes are not intact or there are air leaks at the connection points
• The mesh filter in the DOSING UNIT is clogged
• The DOSING UNIT discharge door is not closed properly during suction.
• The thermal circuit breaker has tripped due to overcurrents and/or short circuits (see previous chapter).
When the cause of the blockage has been eliminated, it is necessary to switch off the light switch for at least 3 seconds, then switch it
on again (indicator light on).
If the problem persists, contact a Service Centre.
MAINTENANCE AND END OF SERVICE LIFE
BEFORE PERFORMING ANY OPERATIONS ON THE PRODUCT, IT IS MANDATORY TO DISCONNECT THE POWER CABLE AND
THE ROOM IN WHICH IT IS INSTALLED MUST BE VENTILATED FOR AT LEAST 15 MINUTES.
COMPLEX MAINTENANCE OPERATIONS OR OPERATIONS THAT TAKE A LONG TIME MUST BE PERFORMED OUTSIDE THE
FUEL STORAGE ROOMS AND THE THERMAL POWER PLANT.
ANY MAINTENANCE OPERATIONS AND REPAIRS MUST BE PERFORMED BY EXPERIENCED PERSONNEL AUTHORISED BY THE
MANUFACTURER.
THE SYSTEM INSTALLER AND THE LOCAL SERVICE CENTRE ARE QUALIFIED TO MAINTAIN THE PRODUCT IN PERFECT WORKING
ORDER.
USING CERTIFIED, LOW-DUST FUELS ENSURES BETTER SYSTEM OPERATION.
PARTS/FREQUENCY
Clean the outside of the product to prevent excessive dust
build-up on the motor. (USER)
Use a brush to remove any traces of dust from the mesh
filter located inside the DOSING UNIT. (USER)
Use a brush to clean the internal rubber side of the DOSING
UNIT fuel discharge door. (USER)
Clean the motor ventilation grilles with compressed air.
(AUTHORISED TECHNICIAN)
Thoroughly clean the fuel storage unit. (AUTHORISED
TECHNICIAN)
END OF SERVICE LIFE
The packaging, the accessories and the appliance must be
disposed of in accordance with current local regulations,
ensuring that the raw materials they are made of are recycled.
EVERY 30 DAYS
X
X
X
ENGLISH
EVERY 6 MONTHS
X
X
31