Designation
Regulations
Charging capacity type 3
Nominal voltage
Nominal current
Nominal frequency
Connection method
Charging connection/charging coupler
Length of charging cable
Operation/ status information
Protection rating
Mechanical impact protection
Residual current detection
Ambient temperature
External Design
Protection class
Overvoltage category
Pollution degree
Sizes
Weight
1.
SAFETY INFORMATION
Please observe the following information for safe
set-up and operation of the Wallbox.
1.1
Information for the operator and
users of the charging system
Read the operating instructions before putting
•
the charging system into operation.
Ensure that all persons working on or using
•
this charging system have read the operating
instructions.
Make sure to follow the regulations and instruc-
•
tions for safe working.
Keep the device documentation in a safe place
•
where it is always accessible to charging system
users.
Ensure that unauthorised persons cannot access
•
the charging system.
1.2
Intended use
The charging system is intended to be used in
the private and semi-public sector, e.g. on private
property, company parking areas or machinery and
equipment yards. Do not use the charging system
in places where potentially explosive or combustible
substances (such as gases, liquids or dusts) are
stored or present. The charging system is intended
exclusively for charging electric vehicles.
Technical Specifications
EN 61851-1; EN 61439-7 (AEVSC)
up to 11 kW
230 V / 400 V / 1/3 AC
up to 16 A adjustable from 6 A to 16 A in 2 A increments
50 Hz
Spring clip method
Type 2
3,5 m (only Home Eco), 5 m or 7.5 m
LED Front Panel (Energy Control)
Pushbutton with LED (Home Eco)
IP54
IK08
DC 6 mA (IEC62955-1)
-25 °C to +40 °C
-25
Wall mounted | Stele mounted
I
III
3
(HxWxD) 386 mm x 295 mm 112 mm
approx. 8kg
Mode 3 charging according to IEC 61851-1
•
Plug and socket connections according to
•
IEC 62196
The charging system is only intended for opera-
•
tion in TT, TNC and TNCS networks. The charging
system must not be operated in IT networks.
The charging system is not suitable for charging
•
vehicles with batteries which produce gas (such
as lead-acid batteries).
The charging system is intended exclusively for
•
stationary installation. The charging system is
suitable for outdoor installation.
Only persons who have read the operating
•
instructions may operate and use the charging
system.
The electrical installation, start-up, and mainte-
•
nance of the charging system may only be per-
formed by qualified electricians who have been
correspondingly authorised by the operator.
The qualified electricians must have read and
•
understood the device documentation and must
comply with its instructions.
Requirements regarding the qualification
of electricians
Knowledge of and compliance with the five safety
rules for working with electrical installations:
English
25