11.
Display Elements Control (Sub-menus will
display when selected for Sonde or line tracing
modes.)
12.
Frequency Selection Control (Sub-menus will
display for categories of frequencies that can
be selected.)
13.
Information Menu including software version
and unit serial number (Sub-menu for restor-
ing factory defaults will display on Information
screen.)
See the Menu Tree on page 36 for a complete list.
SimulTrace Mode
The SimulTrace mode is off by default and can be activated by
selecting it in the Frequency Selection Control sub-menu. It pro-
vides simultaneous tracing of a 512 Hz Sonde and a 33 kHz line
for easier tracking of underground pipes using a Sonde.
Currently Available Sonde Frequencies
Frequencies that have been set to "Checked-Active" status ap-
pear with a check box next to them. If the checkbox is checked,
the frequency can be accessed using the Frequency Key
Frequencies are checked or unchecked by highlighting them
and pressing the Select Key. To return to the operating screen,
press the Menu Key. See the Frequency List on page 10.
Currently Available Active Line Trace Frequencies
Frequencies that have been set to "Checked-Active" status ap-
pear with a check box next to them. If the checkbox is checked,
the frequency will be activated and can then be accessed using
the Frequency Key
. Frequencies are checked or unchecked by
highlighting them and pressing the Select Key. To return to the
operating screen, press the Menu Key. See the Frequency List on
page 10.
Currently Available Passive Line Trace Frequencies
As with other frequency categories, these items will appear in
the "Checked-Active" set when checked. See the Frequency List on
page 10.
Currently Available Radio Frequencies
As with other frequency categories, these items will appear in
the "Checked-Active" set when checked. See the Frequency List on
page 10.
OmniSeek Mode
The OmniSeek mode allows simultaneous tracing in multiple
high-frequency bands: <4 kHz, 4 - 15 kHz, and 15 - 35 kHz.
Change of Depth Units
The SR-60 can display Measured Depth in either Feet or Meters
(Figure 48). Feet are shown in feet-and-inches format; meters are
in decimal format. To change these settings, highlight the Depth
Units selection in the menu and press the Select Key to toggle
between feet or meters. Use the Menu Key to save the section
and exit.
.
Figure 48: Selecting Units (Feet/Meters)
Back Light Control
A light detector built into the upper left corner of the keypad
senses low light levels. The backlight can be forced on by block-
ing the light to this sensor.
The automatic LCD backlight is factory set to only switch on un-
der fairly dark conditions. This is to conserve battery power. As
the batteries near depletion, the backlight will appear dim.
To set the backlight to be always off, highlight the light bulb icon
in the tools section of the menu. Press the Select Key to toggle it
between Auto, always ON and always OFF.
Ridge Tool Company
SeekTech SR-60
31