ENGLISH
– Keep heater and cylinder in an upright position
during operation.
– Before attaching propane make sure Control
Knob on heater is in "OFF" position; see Figure
4.
– Be sure to inspect all connections for leaks,
by using a 50/50 mixture of dish soap and
water on all connection. Any bubbles forming
indicate a leak.
– Follow operating instructions for your model.
Shut Down Instructions Using 1 Lb. Disposable
Cylinder
– To shut off heater, slightly push down and turn
Control Knob clockwise to "OFF" position.
!
CAUTION: After turning heater off, wire
guard will remain hot. Allow guard to cool
before handling and storing.
– Do not operate, store, or remove cylinder near
flammable items or ignition sources.
– A cylinder shall be stored outdoors in a well
ventilated area out of the reach of children.
A disconnected cylinder shall have dust caps
tightly installed and shall not be stored in a
building, garage, or any other enclosed area.
– LP-GAS CYLINDERS MUST BE
DISCONNECTED FROM HEATER WHEN NOT
IN USE!
Shut Down Instructions Using 20 Lb. Tank
– To shut off heater, shut off propane at supply
tank first, allow heater to use up propane in
supply line until heater shuts off, then slightly
push down and turn Control Knob clockwise to
"OFF" position.
!
CAUTION: After turning heater off, wire
guard will remain hot. Allow guard to cool
before handling and storing.
– Do not operate, store, or remove cylinder near
flammable items or ignition sources.
– Cylinders must be stored outdoors out of the
reach of children and must not be stored in a
building, garage, or any other enclosed area.
– LP-GAS CYLINDERS MUST BE
DISCONNECTED FROM HEATER WHEN NOT
IN USE!
!
DANGER: CARBON MONOXIDE
POISONING MAY LEAD TO DEATH!
Figure 2
Figure 3
Figure 4
10