SAFETY INFORMATION (CONT.)
of not less than 1 in
stored fuel capacity.
– Ventilation opening(s) shall be provided
at floor level of the enclosure and shall
have a total free area of not less than 1/2
in
/lb (7.1 cm
2
2
If ventilation openings at floor level are
in a sidewall, there shall be at least two
openings. The bottom of the openings
shall be 1 in (25.4 mm) or less from the
floor level and the upper edge no more
than 5 in (127 mm) above the floor level.
The openings shall be equally sized,
spaced at a minimum of 90 degrees (1.57
rad), and unobstructed.
– Every opening shall have minimum
dimensions to permit the entrance of a 1/8
in (3.2 mm) diameter rod.
– Ventilation openings in sidewalls shall
not communicate directly with other
enclosures of the heater.
MODEL
HH-09SLN-A
4,500 BTU
9,000 BTU
18,000 BTU
WARNING: RISK OF FIRE! ALWAYS
!
LOCATE HEATER ON A STABLE AND
LEVEL SURFACE!
WARNING: NEVER LEAVE HEATER
!
UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR
WHILE CONNECTED TO A FUEL SOURCE.
WARNING: Use only disposable cylinders
!
marked with the proper fuel type.
– Do not leave this appliance unattended
while in operation. Keep children and
pets away from the appliance at all times.
/lb (14.2 cm
/kg) of
2
2
/kg) of stored fuel capacity.
HH-18SLN-A
LOW
LOW
HIGH
MEDIUM
HIGH
– A propane fired portable heater used for
emergency home use shall not be set a
an input setting in excess of 5,000 BTU/
Hr (466 W) when located in a bathroom
and shall not be set at an input setting of
more than 10,000 BTU/Hr (2,931 W) when
located in a bedroom. The corresponding
settings for bedroom or bathroom use
shall be clearly adjustment means.
– Items stored under the heater will be
subject to radiant heater and could be
seriously damaged.
– Children and adults should be alerted to
the hazards of high surface temperatures
and should stay away to avoid burns or
clothing ignition.
– Any guard or other protective device
removed for servicing the heater must be
replaced prior to operation of the heater.
– Installation and repair should be done
by a qualified service person. The heater
should be inspected before use and
at least once every year by a qualified
service person. More frequent cleaning
may be required as necessary. It is
imperative that the control compartment,
burners, and circulating air passageways
of the heater be kept clean.
– Appliance may shut down in windy
conditions in excess of 3 miles per hour
(4.83 kilometers per hour).
– When a heater is used with a remote
propane cylinder the user must ensure
that the propane cylinder meets
specifications for self-contained propane
gas cylinder enclosures, outlined on page