6 CONTROLS
6.5.6 PIN________________________________________________________________
Enter Pin
1 0 0 1
_ _ _ _
This screen gives access to the following parameters and machine functions that can be altered:
• Cross Cut
• Weight Transfer
• Set Default Parameters
• Change PIN
The default owner's Pin is 1001, however Ransomes Jacobsen recommend this is changed.
6.5.7 CROSS CUT ________________________________________________________
Cross Cut function raises the cutting units to a partially raised position, al-
lowing the operator to avoid obstructions without having to fully lift the cut-
ter deck. The Cutter PTO will disengage within 3 seconds of reaching
Cross Cut position. If lowered again within 2 minutes the Cutter PTO will
re-engage automatically. After 2 minutes of continued use in Cross Cut the
PTO will have to be manually reactivated using the PTO switch.
Cross cut function on the F305 is mechanically controlled via a foot oper-
ated lever (A) on the Operator Platform. The units will only lift to cross cut
position unless this lever is pressed, enabling the units to fully lift. (Sec-
tion.6.7).
Cross cut function on the F407 is both mechanically controlled via the foot operated lever (A) for the centre units
and electronically controlled for Wing units.
Setting Cross Cut:
Using the PIN Menu, Buttons 2 and 3 to arrow up and down, and Button
4 to select Cross Cut, this gives you the option to Enable or Disable
• Disabled - The units will only lift while the lift joystick is held
• Enabled - The units will lift to a predetermined height with a short single
activation of the lift joystick
To activate Cross Cut, with the cutting units in lowered position move the
Lift /Lower switch momentarily to the rear in a quick motion. To deactivate,
move the switch lever fully forward. refer to (Section 6.7)
en-40
Enter Pin
Enter Pin
PIN Menu
Cross Cut
Weight Transfer
Set Default Parameters
Change PIN
A
Cross Cut
Disabled
Enabled