Descargar Imprimir esta página

Motorola Solutions PMPN4593 Guia Del Usuario página 22

Publicidad

Idiomas disponibles

Idiomas disponibles

MN008300A01-AB
Chapter 5 : Charging Procedure
5.1.2
Motorola Solutions non-IMPRES Batteries
Table 7: Motorola Solutions non-IMPRES Batteries
Status
Charger Powers On
Battery Detected
Rapid Charging
Charged to 90 % or more
Charged to 95 % or more
Fault
Standby
Battery is waiting to rapid
charge.
Battery may be too hot, too
cold or low voltage.
5.1.3
Unknown Battery
Some unknown batteries may not be detectable by the charger. Unknown batteries do not declare
charging parameters in a manner recognizable by the charger. If an unknown battery is detected, then
the charger indicates charging as summarized in the following table.
Table 8: Charging Unknown Batteries
Status
Charger Powers On
22
Charger Display
IMPRES 2 CHARGER
MOTOROLA SOLUTNS BAT-
TERY
RAPID CHARGE
TRICKLE CHARGE
CHARGE COMPLETE
WARNING: NOT
CHARGEABLE RE-
MOVE & REINSERT
WARNING: HOT
BATTERY WAITING
TO CHRGE or COLD
BATTERY WAITING
TO CHRGE or
VERY LOW BAT-
TERY WAITING TO
CHRGE
Charger Display
IMPRES 2 CHARGER
LED Indicator
Green for approximately one
second
Steady Red
Steady Red
Blinking Green
Steady Green
Blinking Red
Blinking Amber
LED Indicator
Green for approximately one
second

Publicidad

loading