Status
Unknown battery
Fault (Battery Faulted)
Standby
Battery is waiting to rapid
charge.
Battery may be too hot, too
cold, or low voltage.
5.3
Lithium-Ion Battery Preparation for Shipment
You can prepare IMPRES 2 or other authentic Motorola Solutions Lithium-Ion batteries for shipment by
air cargo.
Table 11: Preparing IMPRES 2 Lithium-Ion Batteries for Shipment
Status
Charger Powers On
Battery Detected
Battery Discharging (Discharg-
ing to selection)
Rapid Charging (Charging to
selection)
Discharge or Charge Com-
plete
Ready to Ship
Charger Display
WARNING: NOT
CHARGEABLE RE-
MOVE & REINSERT
WARNING: HOT
BATTERY WAITING
TO CHRGE or COLD
BATTERY WAITING
TO CHRGE or
VERY LOW BAT-
TERY WAITING TO
CHRGE
Charger Display
IMPRES 2 CHARGER
IMPRES 2 BATTERY
SHIP LI DISCHRG xx%
Rated Cap
SHIP LI CHARGE xx%
Rated Cap
SHIP LI DISCHRG or LI
READY TO SHIP xx% Rat-
ed Cap
MN008300A01-AB
Chapter 5 : Charging Procedure
LED Indicator
Blinking Red
Blinking Amber
LED Indicator
Green for approximately one
second
Battery requires Discharge:
Steady Amber
Battery requires Charge:
Steady Red
Steady Amber
Steady Red
Steady Green