DESCRIPTION
Compressed air powered reciprocating piston pump. This high flow capacity pump is compatible with mineral and synthetic oils and suitable for
large installations with long length piping supplying several fluid outlets simultaneously.
This pump can be mounted on the wall, with wall mounting bracket (Part. No. 360132).
WARNINGS
WARNING! Read all instruction manuals, tags, and labels
!
before operating the equipment. This equipment is for
professional use only.
• The use of non compatible fluids may cause damage in the pump and
serious personal injury. This equipment is not intended for use with
fluids that fall within the Group 1 fluid as defined that are explosive,
extremely flammable, highly flammable, flammable, very toxic, toxic,
oxidizing or where the vapor pressure if greater than 0.5 bar above
the pressure atmospheric at the maximum allowable temperature.
• The pump generates high or very high pressures. Do not exceed the
maximum air inlet pressure of 12 bar.
• A direct hit against the human body may result in an injury.
• This unit may have stored pressure, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of
this unit, all service work should be by qualified personnel only.
INSTALLATION
This pump can be mounted directly on the wall, using the
bracket (360132). Firmly fix the bracket to the wall. Put the pump on it
and fix with included screws (Fig. 2).
In those cases in which it is required to comply with ATEX
conditions, be sure to ground the pump with the cable equipped with a
clamp (534907).
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
• When not in use, be sure to shut off the air supply to avoid accidents.
• Do not alter or modify this equipment. Use only Samoa Industrial, S.A.
genuine components. Any unauthorized tampering with this
equipment, improper use, poor maintenance or removal of
identification labels may invalidate the guarantee.
• All fittings in the system connected to the outlet of the pump should
be suitable for the maximum possible pressure generated by the
pump/air motor. If the systems cannot be designed to take the
maximum pressure produced by the pump, safety valves or diverter
valves should be fitted.
• User must respect the surface temperature considerations in explosive
atmospheres. This manual specifies conditions in this regard. The
ATEX marking states the maximum temperature that the equipment
can reach in use, which will depend on that of the oil and/or ambient,
and should be taken into account.
A
534907
EN
Fig. 2
B
360132
3
R. 02/23 853 805