Descargar Imprimir esta página

MBM FB74AXS Manual De Uso E Instalación página 35

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 79
locked doors, protective casing.
• All the zones within the control units,
electrical cabinets and junction boxes.
• All the zones around the appliance
in operation when the minimum safe-
ty distances are not being respected.
EQUIPMENT REQUIRED
FOR INSTALLATION /
The authorised technical operator, in
order to perform the installation ope-
rations correctly, must respect the fol-
lowing requirements:
- 3 and 8 mm screwdriver / medium
size Philips-head screwdriver
- Adjustable pipe wrench
- Gas use tools (hoses, gaskets etc.)
- Electrician's scissors
- Water use tools (hoses, gaskets etc.)
- 8 mm hex socket wrench
- Gas leak detector
- Tools for electric use (cables, termi-
nal blocks, industrial sockets etc.)
- 8 mm nut driver
- Complete installation set (ele, gas etc.)
In addition to the tools listed, an
equipment lifting device is requi-
red. This equipment must com-
ply with all the regulations relating to li-
fting equipment.
INDICATION ON RESIDUAL RISK /
Even though the rules for "good man-
ufacturing practice" and the provisions
of law which regulate manufacturing
and marketing of the product have
been implemented, "residual risks" still
remain which, due to the very nature of
the appliance, it has not been possible
to eliminate. These risks include:
RESIDUAL
ELECTROCUTION / This risks
remains when intervening on live
electrical and/or electronic devices.
RESIDUAL RISK OF BUR-
NING / This risks remains when
unintentionally coming into con-
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
GENERAL AND SAFETY INFORMATION
RISK
OF
- 7 -
tact with materials at high temperatures.
RESIDUAL RISK OF BURNS
DUE TO LEAKING OF MATE-
RIAL / This risks remains when
unintentionally coming into contact with
materials at high temperatures. Contai-
ners that are too full of liquids or solids
that during warming change morpholo-
gy (changing from a solid to a liquid),
can, if used incorrectly, cause burns.
During operations, the containers used
must be placed on easily visible levels.
RESIDUAL RISK OF CRU-
SHING LIMBS / This risk exists
where there is accidental contact
between the parts during positioning,
transportation, storage and assembly.
RESIDUAL RISK OF EXPLO-
SIONS / This risk remains when:
• there is smell of gas in the room;
• appliance used in an atmosphe-
re containing substances which risk
exploding;
• using food in closed containers (such
as jars and cans), if they are not sui-
table for the purpose.
RESIDUAL RISK OF FIRE /
This risk exists by flammable li-
quids / material flammable
OPERATIONAL MODE FOR A
SMELL OF GAS IN THE ENVI-
RONMENT - see SECTION IMA-
GES - REFERENCES a).
If there is a smell of gas in the
environment, it is mandatory
to urgently implement the
procedures described below.
Immediately stop the gas supply
(Close the network tap, detail A).
Ventilate the room immediately.
Do not operate any electrical de-
vice in the environment (Detail
2.
EN

Publicidad

loading