Wall-Mounting The Pbx - Auerswald COMpact 5200 Manual De Instrucciones

Centralita para telefonía analógica, rdsi y por internet
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
• Only a qualified electrician may open the casing and perform installation work within an
open casing.
Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
of the power supply unit (for instance ringer voltages). Work on active, contact-hazard-
ous parts is only permitted after creating a voltage-free state. Working close to active parts
is only permitted if these parts are voltage-free or are protected against direct contact.
• Disconnect the power plug of the PBX and its accessories before instructing a qualified
electrician to open the casing. Also disconnect the device from additional power sources
(e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after disconnecting
it from the main power supply.
• Only operate the device when the casing is closed.
• Only operate the device mounted on the wall.
• Do not remove the covers of the power supply unit and the mainboard. They are a protec-
tion against accidental contact with hazardous voltages and guide the modules. Make
sure that any repairs requiring the casing cover to be removed are carried out by the man-
ufacturer.
Warning: Power surges, which may occur during electrical storms, can cause life-
threatening electric shocks, or damage or destroy the PBX.
• Do not touch the PBX or any devices connected to it during an electrical storm.
1.
Unlatch both locks simultaneously by com-
pressing each with thumb and index finger.
2.
Lift the cover and remove it completely from
the casing.

Wall-Mounting the PBX

Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks.
• Mount the PBX close of an earth wire (potential compensation bar of the house installation
or protective earth conductor). Connect the PBX's earth connection to the earth wire with
a connecting cable whose conductor diameter is at least 2.5 mm
Warning: Liquid entering the casing can cause life-threatening electric shocks or
damage or destroy the PBX.
• Only operate the PBX in closed, dry rooms.
Caution: Overheating can damage or destroy the system.
• Note the ambient temperature values indicated in the technical data.
COMpact 5200/5200R/5500R - Instructions V01 03/2017
Commissioning (COMpact 5200)
²
.
41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Compact 5200rCompact 5500r

Tabla de contenido