ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE
INSTRUCTIONS
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magneto thermic
type upstream, (omni polar with minimum opening of the contacts of 3 mm)
with a check of conformity to the international standards. Such device must be
protected against the accidental lockup (for example by installing inside a locked
board).
2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F
type with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and
installation standards in force in your country.
3° - Positioning of a possible couple of photoelectric cells: the radius of the
photoelectric cells must be at a height of no more than 70 cm from the ground
and at a distance not superior to 20 cm from the motion plane of the door. Their
correct working must be verified at the end of the installation in accordance with
the EN 16005
4° - To fulfill the limits set by EN 16005, and in case the peak force exceeds the
normative limit of 400 N it is necessary to have recourse to the active presence
survey on the whole height of the door (up to max 2,5 m) - The sensors, in this
case, must be applied in accordance with the EN 16005.
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° - This handbook is exclusively addressed to the specialized personnel who
knows the constructive criteria and the protection devices against accidents
for motorized gates, doors and main doors (follow the standards and the laws
in force).
2° - The installer will have to issue a handbook to the final user in accordance with
the 12635.
3° - Before proceeding with the installation, the installer must forecast the risks
analysis of the final automatized closing and the safety of the identified
dangerous points (Following the standard EN 16005).
SYSTEM LAYOUT
2
Technical data
Maximum dimensions of the automation
Height x Depth x Length
Maximum weight of 1-leaf door
Maximum weight of 2-leaf doors
Maximum opening and closure speed 1 leaf sliding door
Maximum opening and closure speed 2 leaf sliding door
Use frequency
Extended range power supply
Nominal power
Stand-by
Output for external accessories supply
Operating temperature
Protection level
Weight
length 1900 mm (minimum automation length)
length 6500 mm (minimum automation length)
1
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
4° - Before installing the motion motor, the installer must verify that the gate is in
5° - The installer must install the member for the manual release at a height inferior
6° - The installer will have to remove possible impediments to the motorized motion
7° - The installer will permanently have to put the tags warning against the deflection
8° - The wiring harness of the different electric components external to the operator
9° - The possible assembly of a keyboard for the manual control of the movement
10° - Keep the automatism controls (push-button panel, remote control etc.) out of
11° - this appliance can be used by children aged from 8 years and above and persons
12° - children shall not play with the appliance
13° - cleaning and user maintenance shall not be made by children without supervision
14° - do not allow children to play with fixed controls. Keep remote controls away
15° - Fixed command devices should be installed in a well visible way.
16° - Before carrying out any installation, regulation or maintenance operation of
17° - At the end of the installation, the installer will have to make sure that the parts
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages
caused by the non observance during the installation of the safety standards and of
the laws in force at present.
SLIDER 2.0 150
150 kg
80+80 kg
2
good mechanical conditions and that it adequately opens and closes.
to 1,8 m.
of the gate (eg. door bolts, sliding bolts, door locks etc.)
on a very visible point or near possible fixed controls.
(for example photoelectric cells, flashlights etc.) must be carried out according
to the EN 16005.
must be done by positioning the keyboard so that the person operating it
does not find himself in a dangerous position; moreover, the risk of accidental
activation of the buttons must be reduced.
the children way. Command device for operating the motor (a switch manually
closed) should be placed in area visible from the guided site and far from moving
parts. It should be placed at least at 1,5 m height.
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved
from children
the system, take off the voltage by operating on the special magneto thermic
switch connected upstream.
of the door do not encumber streets or public sidewalks.
120 x 150 x 6600 mm
0,8 m/s
1,6 m/s
S3 = 100%
100÷240 V~ 50/60 Hz
70 W
3 W
24 Vdc 1 A MAX
-15°C ÷ +50°C
Battery: -10°C ÷ +50°C
IP20
18 Kg
30 Kg
SLIDER 2.0 200
200 kg
130+130kg