10.3 ELECTRONIC CONTROL TERMINAL BOARDS
TS
OS-R
+24V
- 24V
TS
OS-L
+24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
TS
CS-I
OP-I
+24V
USB
- 24V
When you connect the safety devices, remove the jumpers of the corresponding terminals.
Terminal J3 (green)
Description
TS
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the fol-
lowing chapters.
N.B. For devices without testing, connect the N.C. contact to the TS/OS-R terminals.
TS /OS-R
N.C. safety contact in opening side B (right hand side of automation view). When the door is opening, opening the contact
causes the slowing down of the door in the last 500 mm (the safety function of the OS-R terminal can be modified using the
advanced parameters menu).
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS/OS-R jumper.
+24V / - 24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/-
24V).
Terminals J10 (black)
Description
TS
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the fol-
lowing chapters.
N.B. For devices without testing, connect the N.C. contact to the TS/OS-L terminals.
TS /OS-L
N.C. safety contact in opening side A (left hand side of automation view). When the door is opening, opening the contact causes the
slowing down of the door in the last 500 mm (the safety function of the OS-L terminal can be modified using the advanced parame-
ters menu).
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS/OS-L jumper.
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/-
24V).
Terminal J16 (green)
Description
TS
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the fol-
lowing chapters.
N.B. For devices without testing, connect the N.C. contact to the TS/CS-E terminals.
TS / CS-E
N.C. safety contact on passage compartment side B (external side of automation view). When the door is closing, opening
of the contact causes movement inversion.
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS – CS-E jumper.
TS / OP-E
N.O. opening contact side B (external side of automation view).
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/-
24V).
Terminals J15 (black)
Description
TS
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the fol-
lowing chapters.
N.B. For devices without testing, connect the N.C. contact to the TS/CS-I terminals.
S
KO
+24V
IO2
- 24V
IO1
+24V
L
- 24V
H
+24V
- 24V
PP
ENTER
ESC
+
-
LK
J2
11
+
-
MOT
ENC
-
J1
BAT
J6
J21 J19
+