11.6 SEL MENU
ID
Description
MODE
Operating mode
SECL
Selector safety level
DLAY
Maintenance time of the unidirectional opening
mode during night stop
SAM1
If in the SIO1/SIO2 menu, the item SAM is selected,
you can choose which operating mode to set when
the contact (SIO1/SIO2) is HIGH
SAM2
If in the SIO1/SIO2 menu, the item SAM is selected,
you can choose which operating mode to set when
the contact (SIO1/SIO2) is LOW
RPEN
Enable remote programmer mode
CODE
Code management (from keypad or from NFC
tags)
CIN
Import codes
COUT
Export codes
SHOW
Display of possible anomalies and operating infor-
mation on the display
Valeurs
Notes
NO
No mode selected
1DPA
Monodirezionale parziale
PA
Parziale
1D
Monodirezionale
CLOS
Porta chiusa
AUTO
Modalità automatica/giorno
OPEN
Porta aperta
NO/CODE
RPEN set to YES allows you to activate the remote
programmer mode, or if set to NO it does not allow you to
enable the remote programmer mode.
1 sec - 5 min
The night stop procedure (night mode) includes passage
using the unidirectional mode, held for the time specified in
DLAY, to allow the exit, but not entrance
CLOS
Door closed
1D
Unidirectional
PA
Partial
1DPA
Partial unidirectional
OPEN
Door open
AUTO
Automatic/day mode
CLOS
Door closed
1D
Unidirectional
PA
Partial
1DPA
Partial unidirectional
OPEN
Door open
AUTO
Automatic/day mode
NO/YES
RPEN set to YES allows you to activate the remote
programmer mode, or if set to NO it does not allow you to
enable the remote programmer mode.
NO
No push
DPRG
Deletion of the remote programmer mode enabling codes
only
DALL
Complete deletion of the code list
DELC
Code deletion
PROG
New code saving for remote programmer mode activation
OPEN
New priority open command code saving
SEL
New code saving for selector unlocking (function selector
mode)
NO/YES
It allows you to import the code list stored on a USB flash drive
*(NOMS)
*If the word NOMS appears, the USB flash drive is not detected
or is absent
NO/YES
It allows you to export the code list on a USB flash drive
*(NOMS)
*If the word NOMS appears, the USB flash drive is not
detected or is absent
ALL
Display of active contacts of the terminal boards + warning
WARN
Warning only
18

Publicidad