The locking device does not lock or
does not unlock the doors.
15
Routine maintenance plan for automatic sliding doors
To guarantee the correct operation and safe use of the automatic door, as outlined in the European standard EN16005, the owner must have professionally
competent staff carry out the routine maintenance.
Except for routine cleaning activities of the fixture and the floor guiding device, it is the owner's responsibility that all the maintenance and repair activities
must be carried out by professionally competent staff.
The following table lists the activities related to ordinary maintenance, and the intervention frequency referring to the automatic sliding door with operation
in standard conditions. In case of more burdensome conditions or sporadic use of the automatic sliding door, the frequency of the maintenance intervention
can be coherently adjusted.
Activity
Disconnect the power supply, open the automation and carry out the
following checks and adjustments.
- Check the correct fastening of all the screws on the components
inside the automation.
- Check the cleaning of the carriages and the sliding guide.
- Check the correct tightening of the belt.
- Check the wear status of the belt and the wheels of the carriages (if
necessary, replace them).
- Check the correct fastening of the doors on the carriages.
- If present, check the lock coupling and operation of the unlocking cord.
Connect the power supply and carry out the following checks and
adjustments.
- Check the correct operation of the command and safety devices.
- Check that the detection area of the safety sensors complies with the
provisions of the European standard EN16005.
- If present, check that the locking device is working correctly.
- Check that the battery-powered device is working properly (if
necessary, replace the battery).
All maintenance, replacement, repair, upgrading, etc. operations must be written on the maintenance register, as requested by the European standard
EN16005, and delivered to the owner of the automatic sliding door.
For possible repair or replacement of products, original spare parts must be used.
15.1 DISPOSAL OF PRODUCTS
INFORMATION FOR USERS
Pursuant to Legislative Decree No.49 on 14 March 2014
"Implementation of Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)"
The crossed bar symbol on the equipment indicates the product at the end of its useful life must be collected separately from other waste. The user should
therefore hand over the equipment will its components at the end of its useful life to suitable electronic and electro-technical differentiated waste collection
centres, or send it back to the dealer on purchasing new, equivalent equipment, exchanging one for another, or 1 to zero for equipment with its longest side
less than 25 cm. Adequate differentiated waste for subsequent sending of the decommissioned equipment for recycling, treatment or disposal which is
environmentally friendly contributes to avoiding possible negative effects on the environment and health and encourages recycling of materials composing
the equipment. Illegal disposal of the product by the user will be prosecuted according to administrative sanctions pursuant to Leg. Decree no.49 on 14 March
2014.
Automation has detected an anomaly.
Wrong connection of the locking device on
electronic control.
The lock coupling brackets, fastened on the carriages,
do not release from the locking device.
Pulling the unlocking cord, the doors do not unlock.
Check the presence of the electrical mains.
Check the battery connection and its efficiency.
Check the closure of 1-EO contact.
Check that the functions selector is in protected mode
(the lock symbol must be lit).
If present, check the position of the locking device and
connection 1-S1.
Check correct connection of the cable colours on the
locking device.
Check adjustment of the position of the lock coupling
brackets.
Check correct fastening of the unlocking cord on the lock
device.
Frequency
Every 6 months or every 500,000 manoeuvres.
Every 6 months or every 500,000 manoeuvres.
N.B. Check the safety functions of the automation and the safety devices at
least once a year.