TS /CS-I
N.C. safety contact on passage compartment side A (internal side of automation view). When the door is closing, opening
of the contact causes movement inversion.
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS – CS-I jumper.
TS / OP-I
N.O. opening contact side A (internal side of automation view).
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J17 (green)
Description
S
Rotary selector signal ACG9429B - ACG9426B (with key)
+24V / -24V
Rotary selector power supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Morsetti J20 (grigio)
Descrizione
L / H /+24V / -24 V
Collegamento BUS (non utilizzato)
Terminals J4 (grey)
Description
KO
N.O. contact of priority opening, to be connected to devices accessible only to authorised staff using keys or codes.
IO2
Input terminal for general use.
Using the ADV menu > SIO2, you can associate the IO2 terminal with a specific function.
IO1
Input terminal for general use.
Using the ADV menu > SIO1, you can associate the IO1 terminal with a specific function.
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J2 (grey)
Description
LK
Output for activation of the electromechanical lock (+/Red - -/Black) (Select the type of lock using TYLK logic)
Terminals J6
Description
ENC
Rapid connector for angular sensor connection (Encoder)
Terminals J1 (green)
Description
MOT
Connector for motor connection
Terminals J9 (green)
Description
MAINS IN
Mains input 100-240Vac 50/60Hz
Connector J7
Description
USB
USB port Enables saving and loading the configuration of the command control unit.
Refer to the USB paragraph.
10.4 ELECTRICAL CONNECTIONS OF FUNCTIONS SELECTOR ACG9429B - ACG9426B (with key)
Connect the terminals (+24V, -24V, S) on the functions selector, using the cable not supplied by us, for terminals (+24V, -24V, S) of the electronic control.
N.B. For lengths over 10 metres, use a cable with 2 twisted pairs.
Symbol
Description
DOOR OPEN
The door is open and remains open.
PARTIAL OPEN
The door is partially open (settable from 10% to 90% of the stroke).
BIDIRECTIONAL TOTAL OPENING
Allows bidirectional door opening.
UNIDIRECTIONAL TOTAL OPENING
Allows unidirectional operation from the internal/external side of the door.
NIGHT CLOSURE
The door closes and remains locked (if a lock is present), disabling the radar.
cod. 31SR0001 selettore via cavo da incasso
cod. 31SR0001 selettore via cavo da incasso
cod. 31SR0003 selettore via cavo da esterno parete cod. 31SR0004 selettore radio da esterno parete
cod. 31SR0003 selettore via cavo da esterno parete cod. 31SR0004 selettore radio da esterno parete
cod. 31SR0001 selettore via cavo da incasso
cod. 31SR0001 selettore via cavo da incasso
POSIZIONE
PORTA APERTA
- A -
La porta si apre e rimane aperta.
MANUALE
- B -
La porta non accetta comandi e si può movimentare manualmente.
APERTURA TOTALE BIDIREZIONALE
- C -
Consente il funzionamento bidirezionale della porta.
APERTURA TOTALE MONODIREZIONALE
- D -
Consente il funzionamento monodirezionale dal lato interno/esterno dell
CHIUSURA NOTTURNA
- E -
12
La porta si chiude e rimane bloccata (se è presente il blocco) disabilitan
cod. 31SR0002 selettore radio da incasso
cod. 31SR0002 selettore radio da incasso
cod. 31SR0002 selettore radio da incasso
cod. 31SR0002 selettore radio da incasso
cod. 31SR0001 selettore via cavo da incasso
cod. 31SR0002 selettore radio da incasso
cod. 31SR0003 selettore via cavo da esterno parete cod. 31SR0004 selettore radio da esterno parete
FUNZIONI SELETTORE

Publicidad

loading