WARN
List of the last 10 warnings
11.4 MEM MENU
ID
Description
FSET
Back to factory settings
FW
Fw upgrade on board
SIN
Settings loading from USB
SOUT
Settings saving on USB key
11.5 ADV MENU (Advanced)
ID
Description
OSSM
Slowing down space of the door during
the opening in case of side safety sensor
activation (OS-R, OS-L)
ATTENTION: when selecting this parameter you
must consider the risk assessment
OSSS
Stopping distance of the door during the
opening in case of side safety sensor
activation
(OS-R, OS-L)
ELLK
Locking operating mode
TYLK
Type of lock
PIPP
Leaf open check enabled
PUCL
Thrust force with door closed (anti-wind
function)
HOLD
Maintenance force with door open (anti-wind
function)
TS
Safety sensors test enabling
PUGO
Push and Go
VTAC
Variable automatic closure time
MOT
Manual sliding configuration of the door
(operation only with door powered)
The warnings are put in the order form the latest to the
oldest (0.xxx ... 9.yyy)
Values
Notes
NO/YES
Name of upgra-
Select the Firmware version to upgrade from those available.
de files
The upgrade files should be inserted in the path -ON-DS/
*(NOMS)
SLIDING/FW/
*If NOMS appears, the USB pen is not detected or absent
NO/YES
Loading files from -ON-DS/SLIDING/SET/
*(NOMS)
*If NOMS appears, the USB pen is not detected or absent
NO/YES
File saving in -ON-DS/SLIDING/SET/
*(NOMS)
*If NOMS appears, the USB pen is not detected or absent
Values
Notes
YES
Reduced speed on all the passage compartment
100 - 500 [mm]
Space in [mm] at reduced speed in the final part of the stroke
(equal to 100mm/s)
NO
Disabled function
NO
Disabled function
100 - 500 [mm]
Stopping distance in [mm] in the final part of the stroke
AUTO
Automatic mode: automatic detection of the lock presence, if
present the locking control adapts to the operating mode of the
door selected
LOCK
Lock always lowered on closed door
UNLK
Lock always unlocked (except in night mode)
LK1
Secure monostable lock (99EB0001-99EB0006)
LK3
Bistable lock (99EB0004)
LK2
Safe monostable lock (99EB0003)
NO/YES
YES = check enabled, on each opening, the open position is
checked by pushing on the leaf stop
NO
No thrust
MAX
3 force levels applied
MED
MIN
NO
No maintenance of open door
MAX
3 maximum strength levels applicable to keep the door in the
MED
open position
MIN
NO/YES
YES = Sensors test enabled
NO/YES
YES = Manual movement of the leaf from closed position causes
opening
NO/YES
YES = In case of heavy passage of people, after 5 consecutive
inversions the door increases the automatic closure time by 5
seconds
OC
Windings open - Manual opening with little friction
SC
Short-circuited motor windings
Manual opening of the door with greater resistance