10
Electrical connections
5
S
TS
KO
OS-R
+24V
IO2
+24V
- 24V
IO1
- 24V
+24V
L
- 24V
TS
H
OS-L
+24V
+24V
- 24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
PP
ENTER
TS
CS-I
OP-I
+24V
USB
ESC
- 24V
Ref.
Code
1
2
3
4
5
10.1 GENERAL ELECTRICAL SAFETY WARNINGS
The installation, electrical connections and adjustments must be carried out in compliance with good practice and the standards in force.
Before connecting the electrical power supply, ensure the plate data correspond to those of the electrical distribution mains. On the power supply
mains, install an omnipolar switch/sectioning device with an opening distance of the contacts equal or over 3mm. This switch must be protected
from unauthorised activations.
Check upstream of the electrical system that there is an adequate differential switch and an overcurrent safety device.
Connect the automation to an efficient earthing system installed as indicated by safety standards in force.
During installation, maintenance and repair operations, disconnect the power supply before opening the casing to have access to the electrical parts.
The electronic parts must be handled using anti-static, conductive wrist straps connected to the ground.
MYONE S.r.l. cannot be held in any way liable if components are installed which are incompatible for safety purposes and for good operation.
For possible repair or replacement of products, only original spare parts must be used.
The nameplate data can be found on the label positioned in the header.
10.2 ELECTRICAL POWER SUPPLY CONNECTION
Use a power supply cable for connection to the power supply mains.
The power supply cable can be connected to an electrical socket (not supplied by us), prepared near the automation head.
If an electrical socket is not present near the automation, connect to the electrical mains as follows: drill the aluminium box at the top, protect
passage of the power supply cable using cable glands (not supplied by us) to eliminate sharp edges which could damage the power cable, and
connect the cable to the electricity supply.
Connection to the electrical power supply, in the section outside automation, must take place via an independent duct and separated from the
connections to the command and safety devices.
4
J2
J6
ENC
Terminals
Description
MAINS IN
Power cable for automation connection to the electricity mains.
CP.LUCE electronic control
MOT
Direct current gearmotor
ENC
Angular sensor
BAT
BATTERY KIT ACG9480
LK
Locking device
+
-
J1
TS
S
OS-R
+24V
+24V
-24V
J21 J19
-24V
L
TS
OS-L
H
+24V
+24V
-24V
-24V
TS
CS-E
OP-E
+24V
-24V
PP
TS
CS-I
OP-I
USB
+24V
-24V
10
3
-
+
- +
- +
KO
IO2
LK
ENC
MOT
BAT
IO1
+24V
-24V
-24V Output
+24V Output
OP-I = Open internal
OP-E = Open external
CS-I = Closing safety internal
CS-E = Closing safety external
OS-L = Opening safety left
OS-R = Opening safety right
TS = sensor test
S = Function selector signal
ENTER
L = BUS low line
H = BUS high line
KO = Priority opening
IO2 = menu ADV STO2
2
IO1 = menu ADV STO1
ESC
N
1
L
J9