Basic menu operation
The available measuring modes are displayed.
 Use the arrow buttons to select the desired mode.
 Confirm with OK.
The settings for a threaded connection can now be
input.
38
Calling up predefined sequence plans
Bolting operations and sequence plans can be
created on the PC independently of the torque
and angle wrench using the SENSOMASTER
software. These data can then be transferred to
the torque and angle wrench. Information on
this can be found in the SENSOMASTER
software online help.
Proceed as follows to call up a sequence plan
which is available on the torque and angle wrench:
 Make sure that no forces are acting on the torque
and angle wrench.
 Switch the torque and angle wrench on.
 Press the MENU button for approx. one second.
DIRECT INPUT and the sequence plans which are
available are shown on the display.
 Use the arrow buttons to select the desired
sequence plan or individual bolting operation.
The summarisation of the parameters stored for this
sequence plan or individual bolting operation is
displayed. This can be acknowledged with OK.
 Confirm with OK.
The sequence plan or individual bolting operation
can now be executed.