7 INFORMATION
7.2 Technical data
Features
POWER
OPERATING TEMPERATURE
TOTAL WEIGHT
WITH PACKAGING
SIZE OF THE PACKAGING
EXTERNAL AIR CONDITIONER
EXTERNAL UNIT WEIGHT
INTERNAL UNIT WEIGHT
TOTAL WEIGHT
AIR CONDITIONER
SIZE OF THE AIR CONDITIONER
SIZE OF THE INTERNAL UNIT
COOLING/HEATING
HEAT PUMP CURRENT
ONSUMPTION
COOLING/HEATING POWER
CONSUMPTION
HEAT PUMP SUPPLY
HEATING CURRENT
CONSUMPTION*
HEATING POWER
CONSUMPTION*
INRUSH CURRENT
INRUSH POWER
COOLANT
QUANTITY
GWP
*in the version with electrical heating elements
1700 Watt Model
230V AC 50Hz
-15°C +45°C
31 kg
810X600X340 mm
base: 26.6 kg
(without heating elements)
27 kg
(with heating elements)
2.4 kg
29 kg
(without heating elements)
29.4 kg
(with heating elements)
766x537x250 mm
485x485x35 mm
2.8A
644W
1.8 A (sleep speed)
3 A (speed 1)
5.4 A (speed 2)
6.7 A (speed 3)
420 W (sleep speed)
700 W (speed 1)
1250 W (speed 2)
1550 W (speed 3)
14A
3200W
R407C
480 g
852 kg CO2 eq
105
2200 Watt Model
230V AC 50Hz
-15°C +45°C
32 kg
810X600X340 mm
powered: 27.6 kg
(without heating elements)
powered: 28 kg
(with heating elements)
2.4 kg
30 kg
(without heating elements)
30,4 kg
(with heating elements)
766x537x250 mm
485x485x35 mm
4.2A
966W
1.8 A (sleep speed)
3 A (speed 1)
5.4 A (speed 2)
6.7 A (speed 3)
420 W (sleep speed)
700 W (speed 1)
1250 W (speed 2)
1550 W (speed 3)
17A
3900W
R407C
480 g
852 kg CO2 eq
EN