Once the component has been bonded, the vehicle must be stored in a protected room for
24 hours (temperature between 18 and 30 °C).
Note. After six hours (P1 adhesive sealant) or after one hour (Beta-
mate adhesive sealant), use a plastic putty knife to remove the
residual adhesive sealant that has been pushed out around the
bonded component and use a suitable cleaning agent to clean it.
Remove the cover cap for the towing lug, clean it with a suitable
cleaning agent and reinsert it into the opening in the bumper spoiler.
If the adhesive tape is disturbed while cleaning the component, the
tape must be removed, the surface must be cleaned and then fresh
tape attached.
The vehicle must not be moved for the remaining time – the adhesive
sealant must dry properly. Once this time has elapsed, remove the
adhesive tapes.
Fig. 21
› Clip the sensors into the bracket for the parking sensors, ensure they are correctly posi-
tioned in accordance with the figure.
Fig. 22
› Bend the free ends of the protective sheet from the double-sided adhesive tape on both
sides of the rear bumper spoiler strip (B) (hereafter simply referred to as "strip") over its
edge.
› Use sandpaper (grain 80) to roughen the points on the strip where the parking sensor
brackets will be adhered (see arrows).
› Then clean and degrease the roughened surfaces with the Terostat 8550 cleaning agent.
Leave to dry for 10 minutes.
› Apply the 4298 activator to the cleaned areas of the strip (B). Leave to dry for 10 minutes.
Fig. 23
› Remove the masking paper from the adhesive tape on the brackets for the parking sensors
and stick these to the inside of the strip as shown in the figure.
Note. Ensure the parking sensor brackets are correctly positioned on
the strip (see figure).
Fig. 24
› Use Terostat 8550 cleaning agent to clean and degrease the points on the bumper spoiler
where the strip will be adhered using double-sided adhesive tape (see arrows). Leave to dry
for 10 minutes.
Fig. 25
› Connect the wiring harness plug to the sensors.