PARAMETER
Code
Name
d.210 Reserved
d.211 Reserved
d.212 Reserved
d.220 Reserved
d.221 Reserved
d.222 Reserved
Monitor of the control bits sent to the
d.250 LCW To PLC (0-7)
internal sequencer. Bit 0 to 7
Monitor of the control bits sent to the
d.251 LCW To PLC(8-15)
internal sequencer. Bit 8 to 15
Monitor of the control bits generated by the
d.252 LCW Fr PLC (0-7)
internal sequencer. Bit 0 to 7
Monitor of the control bits generated by the
d.253 LCW Fr PLC(8-15)
internal sequencer. Bit 8 to 15
Monitor of the control bits generated by the
d.254 LCW FrPLC(16-24)
internal sequencer. Bit 16 to 24
d.255 LSW (0-7)
Monitor of the drive status. Bit 0 to 7
Number of encoder pulses, recorded in the
d.300 EncPulses/Sample
time interval defined by parameter I.504.
Encoder frequency reading (Motor
d.301 Encoder freq
frequency)
d.302 Encoder speed
Encoder speed reading (d.000)*(P.600)
d.350 Reserved
d.351 Reserved
d.353 Reserved
d.354 Reserved
d.400 PID reference
PID reference signal
d.401 PID feedback
PID feedback signal
d.402 PID error
PID error signal
d.403 PID integr comp
PID integral component
d.404 PID output
PID output signal
d.450 Mdplc error
Status of internal sequencer
Space needed to accelerate the car from
d.500 Lift space
zero to max speed and then decelerate
back to zero
Space needed to accelerate the car from
d.501 Lift accel space
zero to max speed
Space needed to decelerate the car from
d.502 Lift decel space
max speed to zero
d.800 1st alarm-latest
Last alarm stored by the drive alarm list
d.801 2nd alarm
Second to last alarm
d.802 3rd alarm
Third to last alarm
d.803 4th alarm
Fourth to last alarm
Drive rated current (it depends on the
d.950 Drive rated curr
drive size)
d.951 SW version (1/2)
Software version - part 1
d.952 SW version (2/2)
Software version - part 2
d.957 Drive size
Drive size code
d.958 Drive cfg type
Drive configuration type
d.999 Display Test
Drive display test
44
DESCRIPTION
0
1
See paragraph 9.3
03.01
00.00
4
5
6
[0]Standard:400
[1]American:460
PICK LIST
Selection
Description
No error
Internal sequencer error
4kW - 230/400/460V
5.5kW - 230/400/460V
7.5kW - 230/400/460V
Standard: 400Vac, 50Hz
American: 460Vac, 60Hz
Def.
Min
Max
Unit
Hz
%
%
%
%
%
m
m
m
Variat.
IPA
66
67
68
69
70
71
1/100
035
0.01
036
0.01/1
037
0.1
041
0.1
042
0.1
043
0.1
044
0.1
045
62
0.01
63
0.01
64
0.01
65
046
047
048
049
0.1
050
0.01
051
0.01
052
057
061
099
AGL50-EV