gefran AGL50-EV Manual De Instrucciones página 53

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PARAMETER
Code
Name
F.060 MltFrq channel 1
Source of the Multispeed 1
F.061 MltFrq channel 2
Source of the Multispeed 2
Frequency reference multiplier factor
F.080 FreqRef fac src
source
F.100 Frequency ref 0
Digital Reference frequency 0
F.101 Frequency ref 1
Digital Reference frequency 1
F.102 Frequency ref 2
Digital Reference frequency 2
F.103 Frequency ref 3
Digital Reference frequency 3
F.104 Frequency ref 4
Digital Reference frequency 4
F.105 Frequency ref 5
Digital Reference frequency 5
F.106 Frequency ref 6
Digital Reference frequency 6
F.107 Frequency ref 7
Digital Reference frequency 7
F.108 Frequency ref 8
Digital Reference frequency 8
F.109 Frequency ref 9
Digital Reference frequency 9
F.110 Frequency ref 10
Digital Reference frequency 10
F.111 Frequency ref 11
Digital Reference frequency 11
F.112 Frequency ref 12
Digital Reference frequency 12
F.113 Frequency ref 13
Digital Reference frequency 13
F.114 Frequency ref 14
Digital Reference frequency 14
Digital refer frequency 15. When in backup
F.115 BakPwr max freq
power mode, it defines the upper limit of
the inverter output frequency
F.116 Smooth start frq
Frequency reference during smooth start
F.201 Acceleration 1
Linear acceleration with ramp set 1
F.202 Deceleration 1
Linear deceleration with ramp set 1
F.203 Acceleration 2
Linear acceleration with ramp set 2
F.204 Deceleration 2
Linear deceleration with ramp set 2
F.205 Acceleration 3
Linear acceleration with ramp set 3
F.206 Deceleration 3
Linear deceleration with ramp set 3
F.207 Acceleration 4
Linear acceleration with ramp set 4
F.208 Deceleration 4
Linear deceleration with ramp set 4
F.250 Ramp S-shape
S-shaped ramp enable
Jerk applied at the beginning of an accele-
F.251 Jerk acc ini 1
ration with ramp sets 1 and 3
Jerk applied at the end of an acceleration
F.252 Jerk acc end 1
with ramp sets 1 and 3
Jerk applied at the beginning of a decele-
F.253 Jerk dec ini 1
ration with ramp sets 1 and 3
Jerk applied at the end of a deceleration
F.254 Jerk dec end 1
with ramp sets 1 and 3
AGL50-EV
DESCRIPTION
[1] Analog inp 1
[2] Analog inp 2
[3] Freq ref x
[4] Multispeed
[5] Motorpotent
[6] Analog inp 3
[7] Encoder
[8] Reserved
[0] Null
[1] Analog inp 1
[2] Analog inp 2
[3] Analog inp 3
[0] Disable
[1] Enable
PICK LIST
Selection
Description
Analog input 1
Analog input 2
Frequency reference
F.101
Multispeed
Motorpotientometer
reference
Analog input 3
Encoder signal
As for F.050, Reference
1 source
As for F.051, Reference
2 source
Null
Analog input 1
Analog input 2
Analog input 2
Linear ramps
S-shaped ramps
Def.
Min
Max
Unit
3
0
8
3
0
8
0
0
3
10
-F.020
F.020
Hz
50
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
0
-F.020
F.020
Hz
5
-F.020
F.020
Hz
2
-F.020
F.020
Hz
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
0.6
0.01
5.0
m/s2
1
0
1
1.00
0.01
10.00
m/s3
1.40
0.01
10.00
m/s3
1.40
0.01
10.00
m/s3
1.00
0.01
10.00
m/s3
Variat.
IPA
309
310
342
0.1
311
0.1
312
0.1
313
0.1
314
0.1
315
0.1
316
0.1
317
0.1
318
0.1
319
0.1
320
0.1
321
0.1
322
0.1
323
0.1
324
0.1
325
0.1
326
0.1
327
0.01
329
0.01
330
0.01
331
0.01
332
0.01
333
0.01
334
0.01
335
0.01
336
337
0.01
343
0.01
344
0.01
345
0.01
346
53

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lift inverter agl50

Tabla de contenido