gefran AGL50-EV Manual De Instrucciones página 51

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PARAMETER
Code
Name
I.311
An out 2 offset
Analog output 2 offset
I.312 An out 2 gain
Analog output 2 gain
I.313 An out 2 filter
Time constant of output filter
Expansion Analog Output 1 configuration
I.350 Exp an out 1 cfg
(on Exp. board)
I.351 Exp AnOut 1 offs
Expansion Analog Output 1 offset
I.352 Exp AnOut 1 gain
Expansion Analog Output 1 gain
I.353 Exp AnOut 1 filt
Time constant of output filter
I.400 Inp by serial en
Virtual Digital enabling
Expansion Virtual Digital
I.410 Exp in by ser en
Inputs enabling
I.420 Out by serial en
Virtual Digital Outputs setting enabling
I.430 Exp OutBySer en
Expansion Virtual Digital Outputs enabling
I.450 An out by ser en
Virtual Analog Outputs enabling
I.500 Encoder enable
Enabling of the encoder measure
I.501 Encoder ppr
Encoder nameplate pulses per revolution
I.502 Enc channels cfg
Encoder channels configuration
Multiplier factor of the encoder pulses, set
I.503 Enc spd mul fact
in the I.501
I.504 Enc update time
Encoder pulses sampling time
I.505 Enc power supply
Encoder power supply level
I.506 Enc fault enable
Enable ENC alarm, Encoder cable break
I.600 Serial link cfg
Serial line configuration protocol & mode
I.601 Serial link bps
Serial line baudrate
I.602 Device address
Serial line address of the drive
AGL50-EV
DESCRIPTION
As for I.300
[0] Disable
[1] Enable
[0] One Channel
[1] Two Channels
[0] 1ms
[1] 4ms
[2] 16ms
[3] 0.25s
[4] 1s
[5] 5s
[0] 5.2V
[1] 5.6V
[2] 8.3V
[3] 8.7V
[0] Disable
[1] Enable
[0] FoxLink 7E1
[1] FoxLink 701
[2] FoxLink 7N2
[3] FoxLink 8N1
[4] ModBus 8N1
[5] JBus 8N1
[0] 600 baud
[1] 1200 baud
[2] 2400 baud
[3] 4800 baud
[4] 9600 baud
[5] 19200 baud
[6] 38400 baud
PICK LIST
Selection
Description
Encoder measure
disabled.
Encoder measure
enabled.
A (K1) encoder channel
A and B (K1 and K2)
encoder channels
Encoder alarm disabled
Encoder alarm enabled
Type(DataBit) Parity
(StopBit)
FoxLink 7E1 (7) Even
(1 )
FoxLink 7O1 (7) Odd (1)
FoxLink 7N2 (7) None
(2)
FoxLink 7O1 (8) None
(1)
Modbus 8N1 (8) None
(1)
Jbus 8N1 (8) None (1)
600 baud rate
1200 baud rate
2400 baud rate
4800 baud rate
9600 baud rate
19200 baud rate
38400 baud rate
Def.
Min
Max
Unit
0
-9.99
9.99
1
-9.99
9.99
0
0
2.5
sec
3
0
22
0
-9.99
9.99
1
-9.99
9.99
0
0
2.5
sec
0
0
255
0
0
15
0
0
15
0
0
3
0
0
255
0
0
1
1024
1
9999
1
0
1
1
0.01
99.99
0
0
5
0
0
3
0
0
1
4
0
5
4
0
6
1
0
99
Variat.
IPA
0.01
138
0.01
139
0.01
140
141
0.01
142
0.01
143
0.01
144
145
146
147
148
149
150
151
152
153
154
181
197
0.1
155
156
1
157
51