PARAMETER
Code
Name
P.380 Autoreset attmps
Number of autoreset attempts
P.381 Autoreset clear
En. automatic reset of autorestart attempts
P.382 Autoreset delay
Autoreset time delay
Alarm relay contacts behaviour during
P.383 Autores flt rly
autoreset
P.400 Ext fault mode
External fault detection mode
P.410 Ph Loss detec en
Phase Loss detection enabling
P.420 Volt reduc mode
Voltage reduction mode
P.421 V reduction fact
Source of voltage reduction factor
P.422 V fact mult src
multiplier
P.440 Frequency thr 1
Frequency 1 level detection
P.441 Freq prog 1 hyst
Hysteresis amplitude related to P-420
P.442 Frequency thr 2
Frequency 2 level detection
P.443 Freq prog 2 hyst
Hysteresis amplitude related to P-422
P.460 Const speed tol
Tolerance at constant speed
P.461 Const speed dly
Ramp end signalling delay
P.480 Heatsnk temp lev
Heatsink temperature signalling level
P.481 Heatsnk temp hys
Hysteresis band related to P.480
P.482 UHS Detect Mode
Activación alarma UHS
P.500 Switching freq
Modulation frequency
P.501 Sw freq reduc en
Enabling of switching frequency reduction
P.502 Min switch freq
Minimum switching frequency
P.520 Overmod max lev
Overmodulation level
P.540 Out Vlt auto adj
Automatic adjustment of output voltage
AGL50-EV
DESCRIPTION
[0] OFF
[1] ON
[0] Alm alw,No AR
[1] Alm run,No AR
[2] Alm alw, ARes
[3] Alm run, ARes
[0] Disable
[1] Enable
[0] Always
[1] Steady state
[0] Null
[1] Analog inp 1
[2] Reserved
[3] Reserved
[0] Disable
[1] Enable
[0] 1kHz
[1] 2kHz
[2] 3kHz
[3] 4kHz
[4] 6kHz
[5] 8kHz
[6] 10kHz
[7] 12kHz
[8] 14kHz
[9] 16kHz
[10] 18kHz
[0] Disable
[1] Enable
As for P.500
PICK LIST
Selection
Description
- Drive in alarm. Alarm
always active. Alarm
autoreset is not possible.
- Drive in alarm. Alarm
active only with running
motor. Alarm autoreset is
not possible.
- Drive in alarm. Alarm
always active. Alarm
autoreset is possible.
- Drive in alarm. Alarm
active only with running
motor. Alarm autoreset is
possible.
Always
Costant speed only
Null
Analog input 1
Def.
Min
Max
Unit
0
0
255
10
0
250
min
5
0.1
50
sec
1
0
1
0
0
3
1
0
1
0
0
1
% of
100
10
100
P.061
0
0
3
0.5
0
F.020
Hz
0.2
0
F.020
Hz
0
0
F.020
Hz
0.5
0
F.020
Hz
0
0
25
Hz
0.1
0
25
sec
70
10
110
°C
5
0
10
°C
0
0
1
(*)
0
(*)
0
0
1
(*)
0
P.500
0
0
100
%
1
0
1
Variat.
IPA
466
1
467
0.1
468
469
470
492
471
1
472
473
0.1
474
0.1
475
0.1
476
0.1
477
0.1
478
0.1
479
1
480
1
481
513
482
483
495
1
484
485